background image

13

WARRANTY

IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman-
ship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or
Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you.
Please provide the equipment model number, serial number and the date of purchase.

IMI Cornelius Offices

AUSTRALIA

 

D

 

P.O.

 

210,

 

D

 RIVERWOOD,

 

D

 NSW

 

2210,

 

AUSTRALIA

 

D

 

(61)

 

2

 

533

 

3122

 

D

 FAX

 

(61)

 

2

 

534

 

2166

AUSTRIA

 

D

 AM

 

LANGEN

 

FELDE

 

32

 

D

 A-1222

 

D

 VIENNA,

 

AUSTRIA

 

D

 

(43)

 

1

 

233

 

520

 

D

 FAX

 

(43)

 

1-2335-2930

BELGIUM

 

D

 BOSKAPELLEI

 

122

 

D

 

B-2930

 

BRAASCHAAT,

 

BELGIUM

 

D

 

(32)

 

3

 

664

 

0552

  

D

 

 FAX

 

(32)

 

3

 

665

 

2307

BRAZIL

 

D

 

RUA

 

ITAOCARA

 

97

 

D

 TOMAS

 

COELHO

 

D

 RIO

 

DE

 

JANEIRO,

 

BRAZIL

 

D

 

 (55)

 

21

 

591

 

7150

 

D

 FAX

 

(55)

 

21

 

593

 

1829

ENGLAND

 

D

 TYTHING

 

ROAD

 

ALCESTER

 

D

 WARWICKSHIRE,

 

B49

 

6

 

EU,

 

ENGLAND

 

D

 (44)

 

789

 

763

 

101

 

D

 FAX

 

(44)

 

789

 

763

 

644

FRANCE

 

D

 71

 

ROUTE

 

DE

 

ST.

 

DENIS

 

D

 F-95170

 

DEUIL

 

LA

 

BARRE

 

D

 PARIS,

 

FRANCE

 

D

 (33)

 

1

 

34

 

28

 

6200

 

D

 FAX

 

(33)

 

1

 

34

 

28

 

6201

GERMANY

 

D

 CARL

 

LEVERKUS

 

STRASSE

 

15

 

D

 D-4018

 

LANGENFELD,

 

GERMANY

 

D

 (49)

 

2173

 

7930

 

D

 FAX

 

(49)

 

2173

 

77

 

438

GREECE

 

D

 488

 

MESSOGION

 

AVENUE

 

D

 AGIA

 

PARASKEVI

 

D

 153

 

42

 

D

 

ATHENS,

 

GREECE

 

D

 (30)

 

1

 

600

 

1073

 

D

 FAX

 

(30)

 

1

 

601

 

2491

HONG

 

KONG

 

D

 1104

 

TAIKOTSUI

 

CENTRE

 

D

 11-15

 

KOK

 

CHEUNG

 

ST

 

D

 TAIKOKTSUE,

 

HONG

 

KONG

 

D

 (852)

 

789

 

9882

 

D

 FAX

 

(852)

 

391

 

6222

ITALY

 

D

 VIA

 

PELLIZZARI

 

11

 

D

 1-20059

 

D

 VIMARCATE,

 

ITALY

 

D

 

(39)

 

39

 

608

 

0817

 

D

 FAX

 

(39)

 

39

 

608

 

0814

NEW

 

ZEALAND

 

D

 20

 

LANSFORD

 

CRES.

 

D

 P.O.

 

BOX

 

19-044

 

AVONDALE

 

D

 AUCKLAND

 

7,

 

NEW

 

ZEALAND

 

D

 

 (64)

 

9

 

8200

 

357

 

D

  FAX

 

(64)

 

9

 

8200

 

361

SINGAPORE

 

D

 16

 

TUAS

 

STREET

 

D

 SINGAPORE

 

2263

 

D

 (65)

 

862

 

5542

 

D

 FAX

 

(65)

 

862

 

5604

SPAIN

 

D

 

POLIGONO

 

INDUSTRAIL

 

D

 

RIERA

 

DEL

 

FONOLLAR

 

D

 

E-08830

 

SANT

 

BOI

 

DE

 

LLOBREGAT

 

D

 

BARCELONA,

 

SPAIN

 

D

 

(34)

 

3

 

640

 

2839

 

D

 

FAX

 

(34)

 

3

 

654

 

3379

USA

 

D

 ONE

 

CORNELIUS

 

PLACE

 

D

 ANOKA,

 

MINNESOTA

 

D

 (612)

 

421-6120

 

D

 FAX

 

(612)

 

422-3255

LD004

4/21/98

Summary of Contents for TEA URN

Page 1: ...ectly connected to a potable water supply shall be sized installed and maintained according to Federal State and Local laws Printed in U S A 94 IMI CORNELIUS INC 1993 94 IMI CORNELIUS INC One Corneliu...

Page 2: ...OX CONCENTRATE SYSTEMS 9 CLEANING THE NITROGEN GAS CHECK VALVE 9 PAGE TROUBLESHOOTING 13 WATER TO CONCENTRATE RATIO OF DIS PENSED PRODUCT TOO LOW OR TOO HIGH 13 ADJUSTMENT OF DISPENSING VALVE CON CENT...

Page 3: ...approximate Shipping 11 pounds Dry Weight 8 pounds Dispensing Rate approx 1 1 2 ounces sec Ambient Operating Temperature 40_F to 100_F Operating Pressures Water Inlet Supply Line 40 to 125 psig FIGUR...

Page 4: ...DIOXIDE CO2 GAS CYLINDER ADJUSTABLE CONCENTRATE FLOW REGULATOR ADJUSTABLE WATER FLOW REGULATOR SHUTOFF VALVE LINE LEGEND WATER CONCENTRATE GAS DISPENSER BAG IN BOX CONCENTRATE CONTAINER CONCENTRATE P...

Page 5: ...Hole Plugs 2 2 9 151707 Screw Thd Rolling 8 32 By 3 8 in long 2 2 IDENTIFICATION OF LOOSE SHIPPED PARTS 1 CUP REST item 1 fits inside DRIP TRAY item 2 2 DRIP TRAY item 2 supports cup rest and receives...

Page 6: ...TS item 3 2 Connect other end of concentrate source line connected to the Unit to outlet fitting on bag in box concentrate pump 3 Connect concentrate source line from bag in box location to inlet fitt...

Page 7: ...To syrup Ratio of dispensed product should be checked periodically and adjusted if necessary Refer to SERVICE AND MAINTENANCE section of this manual for adjustment procedure ADJUSTING PRIMARY CO2 REG...

Page 8: ...ECK VALVES The CO2 gas check valve must be inspected and serviced as instructed at least once a year under normal conditions and after any CO2 system servicing or disruption Servicing of CO2 gas check...

Page 9: ...the amount of water was too much turn dispensing valve water flow regulator adjusting screw Figure 3 counterclockwise a quarter of a turn at a time Repeat dispensed water measurement after each adjust...

Page 10: ...leaning instructions is to remove only external residue from the valve and it s baffle and nozzle 1 Remove acorn nut securing dispensing valve cover then remove cover 2 Remove nozzle and baffle assemb...

Page 11: ...n the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area before attempting to repair the leak Personnel exposed to...

Page 12: ...G CO2 SYSTEM CO2 GAS CHECK VALVES see Figures 2 and 4 The primary CO2 regulator CO2 gas check valve must be inspected and serviced at least once a year under normal conditions and after any servicing...

Page 13: ...mp A Adjust primary CO2 regulator or check CO2 supply and replenish as instructed B No concentrate supply B Replenish concentrate supply as instructed C Quick disconnect not secure on bag in box conta...

Page 14: ...d E Adjust Water to Concentrate Ratio of dispensed product as instructed F No CO2 gas supply F Replenish CO2 gas supply as instructed G Dispensing valve concentrate flow regulator bag in box quick dis...

Page 15: ...TER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL L...

Page 16: ...ag in box hookup This revised manual was never released on a PCN Talked to George Murphy about this 08 11 94 and he said not to be in a hurry to release the revised manual as they have a rather large...

Reviews: