5. Place the ratio cup on a level surface and note

the concentrate and water levels. The
concentrate and water levels should be the
same.

6. If concentrate and water levels are not the

same, turn the concentrate flow regulator
adjusting screw (Figures 3) counterclockwise
1/4 turn for less concentrate or clockwise 1/4
turn to provide more concentrate.

WATER

CHAMBER

WATER FLOW

REGULATOR

CONCENTRATE

FLOW REGULATOR

DISPENSING

VALVE

CONCENTRATE BY-PASS

ASS’Y (P/N 318759-000)

RATIO CUP

 (P/N 311100-000)

FIGURE 3. RATIO CUP AND CONCENTRATE

BY-PASS ASS’Y (SF-1 SINGLE FLAVOR

DISPENSING VALVE)

7. Repeat Water-To-Concentrate “Ratio” test and

adjust concentrate flow regulator as many times
as necessary until proper ratio of dispensed
drink is achieved.

8. Replace dispensing valve cover and secure

with  acorn nut.

CLEANING AND SANITIZING

DAILY CLEANING

1. Remove cup rest from drip tray.

2. Wash drip tray in place on Unit,

3. Wash cup rest, then rinse cup rest with clean

water. Install cup rest in drip tray.

4. Clean all external surfaces of Unit with sponge.

Rinse out sponge with clean water, then wring
excess water out of sponge and wipe off
external surfaces on Unit. Wipe until dry with a
clean soft cloth. DO NOT USE ABRASIVE
TYPE CLEANERS.

WEEKLY CLEANING OF DISPENSING VALVE

The following dispensing valve cleaning instructions
are done without removing the valve from the Unit.
The purpose of these cleaning instructions is to
remove only external residue from the valve and it’s
baffle and nozzle.

1. Remove acorn nut securing dispensing valve

cover, then remove cover.

2. Remove nozzle and baffle assembly from valve.

3. Place waste container under the dispensing

valve.

4. Slowly pour warm water over the dispensing

valve.

5. Wash nozzle and baffle assembly in warm water

only. Use of detergents may give the product an
off-flavor.

6. Install baffle and nozzle assembly on the

dispensing valve. Low pressure gas may be
used to blow excess water off valves.

7. Place cover on the dispensing valve and secure

with acorn nut.

SANITIZING CONCENTRATE SYSTEM

IMPORTANT: Only qualified personnel should
perform sanitizing procedure.

The concentrate system should be sanitized every
90 days following Sanitizer Manufacturer’s
recommendations. Use Chlor-tergent (Oakite
Products Inc.) or equivalent sanitizer. Proceed as
follows.

1. Close plain water inlet line shutoff valve to the

Unit.

2. Disconnect concentrate line quick-disconnect

connector from the bag-in-box concentrate
container.

3. Wash the concentrate line quick disconnect

connector in warm  water.

4. Using a clean plastic 5-gallon container, prepare

4 gallons of sanitizing solution as follows:

A.

Pour 4 gallons of water at a temperature
between 70

°

 F to a maximum of 100

°

 F

into the 5-gallon container.

B.

Add to the container and mix thoroughly
0.67 ounce of Chlor-Tergent or equivalent
sanitizer per gallon to provide a solution of
200 ppm of chlorine.

5. Install a bag valve cut from an empty bag-in-box

container on the concentrate line quick
disconnect connector.

Summary of Contents for TEA URN

Page 1: ...ectly connected to a potable water supply shall be sized installed and maintained according to Federal State and Local laws Printed in U S A 94 IMI CORNELIUS INC 1993 94 IMI CORNELIUS INC One Corneliu...

Page 2: ...OX CONCENTRATE SYSTEMS 9 CLEANING THE NITROGEN GAS CHECK VALVE 9 PAGE TROUBLESHOOTING 13 WATER TO CONCENTRATE RATIO OF DIS PENSED PRODUCT TOO LOW OR TOO HIGH 13 ADJUSTMENT OF DISPENSING VALVE CON CENT...

Page 3: ...approximate Shipping 11 pounds Dry Weight 8 pounds Dispensing Rate approx 1 1 2 ounces sec Ambient Operating Temperature 40_F to 100_F Operating Pressures Water Inlet Supply Line 40 to 125 psig FIGUR...

Page 4: ...DIOXIDE CO2 GAS CYLINDER ADJUSTABLE CONCENTRATE FLOW REGULATOR ADJUSTABLE WATER FLOW REGULATOR SHUTOFF VALVE LINE LEGEND WATER CONCENTRATE GAS DISPENSER BAG IN BOX CONCENTRATE CONTAINER CONCENTRATE P...

Page 5: ...Hole Plugs 2 2 9 151707 Screw Thd Rolling 8 32 By 3 8 in long 2 2 IDENTIFICATION OF LOOSE SHIPPED PARTS 1 CUP REST item 1 fits inside DRIP TRAY item 2 2 DRIP TRAY item 2 supports cup rest and receives...

Page 6: ...TS item 3 2 Connect other end of concentrate source line connected to the Unit to outlet fitting on bag in box concentrate pump 3 Connect concentrate source line from bag in box location to inlet fitt...

Page 7: ...To syrup Ratio of dispensed product should be checked periodically and adjusted if necessary Refer to SERVICE AND MAINTENANCE section of this manual for adjustment procedure ADJUSTING PRIMARY CO2 REG...

Page 8: ...ECK VALVES The CO2 gas check valve must be inspected and serviced as instructed at least once a year under normal conditions and after any CO2 system servicing or disruption Servicing of CO2 gas check...

Page 9: ...the amount of water was too much turn dispensing valve water flow regulator adjusting screw Figure 3 counterclockwise a quarter of a turn at a time Repeat dispensed water measurement after each adjust...

Page 10: ...leaning instructions is to remove only external residue from the valve and it s baffle and nozzle 1 Remove acorn nut securing dispensing valve cover then remove cover 2 Remove nozzle and baffle assemb...

Page 11: ...n the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area before attempting to repair the leak Personnel exposed to...

Page 12: ...G CO2 SYSTEM CO2 GAS CHECK VALVES see Figures 2 and 4 The primary CO2 regulator CO2 gas check valve must be inspected and serviced at least once a year under normal conditions and after any servicing...

Page 13: ...mp A Adjust primary CO2 regulator or check CO2 supply and replenish as instructed B No concentrate supply B Replenish concentrate supply as instructed C Quick disconnect not secure on bag in box conta...

Page 14: ...d E Adjust Water to Concentrate Ratio of dispensed product as instructed F No CO2 gas supply F Replenish CO2 gas supply as instructed G Dispensing valve concentrate flow regulator bag in box quick dis...

Page 15: ...TER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL L...

Page 16: ...ag in box hookup This revised manual was never released on a PCN Talked to George Murphy about this 08 11 94 and he said not to be in a hurry to release the revised manual as they have a rather large...

Reviews: