Pinnacle 2 and 4 Flavor Service Manual
S
ECTION
2: S
HUT
-O
FF
V
ALVE
AND
B
LENDONATOR
O
UTLET
B
RIX
S
AMPLE
T
UBE
P
ROCEDURE
The BRIX menu allows the activation of syrup and water solenoids, and blendonator pump motor for a
selected cylinder.
1. Press MENU.
2. Scroll up to BLENDONATOR.
3. Turn Blendonators 1 and 2 OFF.
4. Drain each Blendonator through the BRIX Sample Valve.
5. Press BACK.
6. Scroll down to BRIX.
7. Press GO.
8. Once the BRIX SELECT menu is selected press GO to partially fill Blendonator #1 with a BRIX sam-
ple.
9. After the sample is complete (Blendonator pump has stopped turning), remove the sample from the
Blendonator (through the BRIX Sample Valve) for refractometer testing.
10. If the BRIX reading is within specification, the BRIX adjustment for this barrel is complete.
11. If the BRIX reading is NOT within specification, adjust the syrup Flow Control to bring the product
within specification (clockwise to increase BRIX, counter-clockwise to decrease BRIX). Adjust Flow
Control in no more than 1/2 turn increments.
12. Repeat step 8 above 3 times, drain the Blendonator, and dispose of this product.
13. Repeat steps 8 and 9 above and measure the sample with the refractometer.
14. Repeat steps 11-13 until the product BRIX is within specification.
15. Repeat steps 8-14 until Blendonator #2 product BRIX is within specification.
16. Scroll to the BLENDONATOR menu and turn both Blendonators ON.
FIGURE 17
WATER
PRESSURE SWITCH AND
WATER REGULATOR
FLOW REGULATOR
AND SOLENOID VALVE
SINGLE
CHECK
VALVE
PRODUCT PUMP
(SYRUP AND WATER
ARE MIXED)
CHECK VALVE
COOLING COIL
FREEZE
CYLINDER
BLENDONATOR
SYRUP
PRODUCT SHUTOFF
VALVE
WATER ICE BATH
PRODUCT SAMPLE VALVE