Pinnacle 2 and 4 Flavor Service Manual
Menu 5 - SET WAKE UP
From the SET WAKE UP menu the system wake up times are set. These are the times when the system
will resume normal operation (freeze cylinder refrigeration and beater motor operation) after an inactive
period (sleep). Each day of the week can have a separate wake up time, or “ALL DAYS” of the week can
be programmed to wake up at the same time.
Each cylinder will wake up in the mode that it was in when it went to sleep. For instance, if cylinder #1
was ON, and cylinder #2 was in MOTOR before going to sleep, the cylinders will wake up in those modes.
Wake up times can be set in 15 minute increments. When NONE appears, it means that no wake up time
has been set for that day. The preset time format used by the system will be used by the SET WAKE UP
menu.
A WAKE UP must be set for every SLEEP.
The wake up program will run a 2 minute defrost, whether it follows a sleep or not, on each barrel before
returning the unit to normal operation.
SET WAKE UP Menu Button Descriptions:
#1 - BACK . . . . . . . go back to the previous menu
#2 - DAY . . . . . . . . . cycle through the list of days
#3 - NEXT . . . . . . . cycle through the time fields
#4 - UP . . . . . . . . . . increase the selected field by 1 hour or 15 minute increment
#5 - DOWN. . . . . . . decrease the selected field by 1 hour or 15 minute increment
To set wake up times:
1. Press <DAY> to select 1 of 8 options (SUNDAY, MONDAY, TUESDAY, WEDNESDAY, THURSDAY,
FRIDAY, SATURDAY, ALL DAYS)
2. Press <NEXT> to change the field from HOURS to MINUTES
3. Press <UP> and <DOWN> to change the setting in the field
4. Press <BACK> to save the changes.
FIGURE 12
Wake Up
Time
Wake Up
Day
© 2003-2014, Cornelius Inc.
- 19 -
Publication Number: 560007298SER
Summary of Contents for FCB - 2 Flavor
Page 75: ......