![Cornelius FCB - 2 Flavor Service Manual Download Page 41](http://html1.mh-extra.com/html/cornelius/fcb-2-flavor/fcb-2-flavor_service-manual_2667818041.webp)
Pinnacle 2 and 4 Flavor Service Manual
Err
o
r
Displa
y
Priority
Er
ro
r R
e
s
e
t
Re
spo
n
se
Sys
te
m
Res
pons
e
D
is
pla
y
Out
put
Comp
Mot
o
r
1
Ble
nd
4
C
o
ndit
ion Af
te
r
Err
o
r Reset
M
e
n
u
1,
3,
13
,1
7
M
en
u 2
0
C
o
mm
unic
ation
1
a
C
ycle
Po
w
e
r
O
FF*
O
F
F
O
FF
OFF
C
OM
M
O
CO
MM
UN
ICA
T
IO
N
Electr
on
ics
1
b
C
ycle
Po
w
e
r
OFF*
OFF
O
FF
O
F
F
E
RR
OR
EL
ECTR
ONICS
Re
al Time
Clo
c
k
1c
Cycle
Po
w
e
r
OFF*
OFF
O
FF
OFF
C
L
O
CK
ERR
O
R
CLOCK
ERR
O
R
H
o
t Gas V
a
lv
e
1
d
C
ycle
Po
w
e
r
OFF*
OFF
O
FF
OFF
OFF
H
O
T
GAS #X
HO
T GAS #X
H
igh
V
o
lt
ag
e
2
a
A
u
to
O
F
F
*
O
F
F
O
F
F
“L
as
t Kn
o
w
n
St
at
e”
of
Syste
m
VO
LT
H
IG
H
V
O
LT
A
G
E
Lo
w V
o
lt
age
2b
A
u
to
OFF*
OFF
O
FF
“L
a
s
t Kno
w
n
St
at
e”
of
Syste
m
VO
LT
L
O
W
V
O
LT
A
G
E
C
y
linder D
riv
e
3
Man
u
al
C
y
linder
OFF*
*
OFF
O
N
“La
st
Kno
w
n
St
at
e”
of
Syste
m
DRIV
E
DRIVE #X
Ov
er
T
o
rque
4
M
an
u
a
l
C
ylind
e
r
OFF*
*
OFF
O
N
“La
st
Kno
w
n
St
at
e”
of
Syste
m
TO
R
Q
U
E
TO
R
Q
U
E
#
X
Cylin
der
Re
fg
5
M
an
u
a
l
O
FF*
OFF
O
N
“La
st
Kno
w
n
St
at
e”
of
Syste
m
REFRIG
BRL REFRIG
#X
Ice Ban
k
Ref
g
6
M
an
u
a
l
O
FF*
OFF
O
N
“La
st
Kno
w
n
St
at
e”
of
Syste
m
REFRIG
IB
REFRIG
#
Y
Sy
ru
p
So
ld
Ou
t
7
A
u
to
C
y
lin
de
r
OFF*
*
M
o
to
r
O
FF
“L
as
t Kn
o
w
n
St
at
e”
of
Syste
m
SYR
U
P
SYR
U
P
#X
C
O
2
So
ld
Ou
t
8
A
u
to
O
FF*
M
o
to
r
O
FF
“L
as
t Kn
o
w
n
St
at
e”
of
Syste
m
CO
2
C
O2
OUT
H
2
O
So
ld
Ou
t
9
A
u
to
O
FF*
M
o
to
r
O
FF
“L
as
t Kn
o
w
n
St
at
e”
of
Syste
m
H2O
H
2O OUT
Cylind
e
r Se
nsor
10
Man
u
al
Cylind
e
r
OFF*
*
OFF
O
FF
“L
a
s
t Kno
w
n
St
at
e”
of
Syste
m
SENSOR
B
RL SENS
O
R
#X
Ice Ban
k
Sen
s
or
10
Man
u
al
IB OFF
**
O
FF
O
F
F
“La
st
Kno
w
n
St
at
e”
of
Syste
m
SENSOR
IB SE
NSOR #Y
F
o
ot
no
te
s:
* - The
compressor as
sociated w
ith this re
fr
iger
ation s
ystem where the
error occurs
will be commanded
OFF (not
“no
longer neede
d).
** - The c
o
mpressor
as
sociated w
ith
this freez
e
cy
linder/ice
bank
will s
top
pro
v
iding cooling
to this
spec
ific
e
v
apor
a
tor
.
1 - The “motor condition me
ans
the motor will
contin
ue oper
ating if
it w
a
s in
oper
ation pr
ior to
the error
. If
the motor w
a
s OF
F it
will remain
OFF
.
2 - The “Beeper”
will giv
e
a
5
beep s
e
quence f
o
r
each ne
w
er
ror
that oc
curs
after a bee
ping s
e
quence
is completed.
3 - The “Cylinder St
atus Light”
of the aff
e
c
ted cylinder will
flash
g
reen at a 1 Hz
r
a
te
(50%
DC) on
all
errors
.
4 - The Blender
will NO
T
respond
to float
activ
a
tions w
e
n “OFF”, and will
respond wh
en “ON
” only is
pre
v
iously
enab
led.
© 2003-2014, Cornelius Inc.
- 37 -
Publication Number: 560007298SER
Summary of Contents for FCB - 2 Flavor
Page 75: ......