Pinnacle 2 and 4 Flavor Service Manual
T
RANSFORMER
R
EPLACEMENT
C
ONTACTOR
R
EPLACEMENT
S
TART
C
OMPONENTS
R
EPLACEMENT
1.
Disconnect the power to the unit.
2.
Remove right side panel (3 screws).
3.
Remove all 4 wires from the transformer, note the
connection locations.
4.
Remove the 2 nuts from the screws and remove the
transformer.
5.
Attach the new transformer with the 2 nuts.
NOTE: The Coil on the Pinnacle Contactor has 24 VAC.
FIGURE 42
6.
Re-attach the wires to the tabs on the transformer.
NOTE: Make sure the wires are replaced in the same location noted in step 3.
1.
Disconnect the power to the unit.
2.
Remove side panel.
3.
Remove contactor/starter cover (1 screw).
Disconnect contactor (2 nuts). Do NOT detach the wires from the contactor yet.
4.
One at a time, remove the wires from the old contactor and connect them to the new contactor.
5.
Secure the new contactor in place, install the cover, and re-attach the side panel.
1.
Disconnect the power to the unit.
2.
Remove side panel.
3.
Unfasten the strap (1 screw).
4.
Replace all start and run components, note connection
locations.
Reassemble, re-connect power, and go through a normal
startup procedure.
FIGURE 43
Transformer (2)
Contactor (2)
Run capacitor
Start capacitor
Start relay
© 2003-2014, Cornelius Inc.