8. Flush the wash water from the system by completing the following steps:
• Turn barrel # 1 blendonator OFF (from BLENDONATOR menu) to prevent more wash water from
entering the blendonator.
• Place container under barrel # 1 dispensing valve. Open the dispense valve and dispense all wash
water from the freeze cylinder and the blendonator. As the wash water level lowers in the freeze cyl-
inder partially close the valve to avoid spurting.
• Use a clean syrup tank (syrup tank system) or a clean 5-gallon pail (bag-in-box system) filled with
plain water.
• Connect the sanitizing fitting to the bag-in-box connector. Put the connector in the bucket of plain
water.
• Turn barrel # 1 blendonator ON (from BLENDONATOR menu) to fill blendonator.
• Fill barrel # 1 with plain water by repeatedly pulling and releasing the faceplate relief valve until
solution comes out.
• Open the dispensing valve until water flows from the valve, then close the valve.
• Open blendonator sample valve (see FIGURE 4) until water flows from the valve, then close the
valve.
• Place barrel # 1 in MOTOR mode (from ON/OFF/MOTOR menu) to start barrel # 1 beater. Allow
beater to operate for 2–minutes, then place barrel # 1 in OFF mode (from ON/OFF/MOTOR menu) to
stop the beater.
9. Sanitize the system by completing the following steps:
• Turn barrel # 1 blendonator OFF (from BLENDONATOR menu) to prevent more plain water from
entering the blendonator.
• Place container under barrel # 1 dispensing valve. Open the dispense valve and dispense all plain
water from the freeze cylinder and the blendonator. As the plain water level lowers in the freeze cylin-
der partially close the valve to avoid spurting.
• Use a clean 5-gallon pail (bag-in-box system) to prepare sanitizing solution. Mix approximately 1
ounce of household bleach per gallon of warm water. When the blendonator runs it mixes with pota-
ble water to give proper mixture.
• Put the sanitizing connector in the bucket of sanitizing solution.
NOTE: This mixture will provide 800-ppm of chlorine. Sanitizing solution will be diluted to approx-
imately 200-ppm inside the blendonator tank after carbonated water has been mixed with the san-
itizing solution.
NOTE: If powder sanitizer is used be sure it is thoroughly dissolved and mixed with the correct
amount of water.
• Turn barrel # 1 blendonator ON (from BLENDONATOR menu) to fill blendonator.
• Fill barrel # 1 with sanitizing solution by repeatedly pulling and releasing the faceplate relief valve
until solution comes out.
• Open the dispensing valve until solution flows from the valve, then close the valve.
• Open blendonator sample valve (see FIGURE 4) until solution flows from the valve, then close the
valve.
• Place barrel # 1 in MOTOR mode (from ON/OFF/MOTOR menu) to start barrel # 1 beater. Allow
beater to operate for at least 10 minutes but not more than 15 minutes. Then place barrel # 1 in OFF
mode (from ON/OFF/MOTOR menu) to stop the beater.
• Turn barrel # 1 blendonator OFF (from BLENDONATOR menu) to prevent more sanitizing solution
from entering the blender tank.