W E E K L Y P R E V E N T I V E M A I N T E N A N C E P R O C E D U R E S
Analog Transducer Wire Inspection
4-34
Bravo™ 8105 Preventive Maintenance Guide
Rev. 2
4
Photograph
Figure 4–2
Limit Switch
Information
The inner limit switch is more vulnerable to damage than the outer limit switch.
Pay particular attention to loose connections or screws on the switch mounting.
If necessary to replace, use only Speedline Electrovert parts.
Analog Transducer Wire Inspection
Introduction
An analog transducer used for width control is mounted on the Rear Load End of
the machine (if applicable).
A wire is attached to the plate mounting the movable rail. The wire is preset at
the factory and should not need adjusted. If the wire become detached or loose,
it is necessary to repair the wire for accurate width measurement.