Unidrive M300/HS30 Quick Start Guide
53
Issue Number: 7
Motor Rpm
= 60 x Frequency / Pole pairs
where
Pole pairs = the numeric value of
Number Of Motor Poles
(Pr
40
) (i.e. 3 for a 6 pole motor)
The frequency used to derive the
Motor Rpm
is the
Final Demand Reference
(Pr
83
). The maximum
and minimum values allow for a 10% over-shoot of the speed.
* With the Unidrive HS30, the maximum is 180,000.0 rpm
Current Magnitude
is the instantaneous drive output current scaled so that it represents the r.m.s.
phase current in Amps under steady state conditions.
Torque Producing Current
is the instantaneous level of torque producing current scaled so that it
represents the r.m.s. level of torque producing current under steady state conditions.
Digital I/O Read Word
reflects the state of digital inputs/outputs 1 to 5 and the relay.
Reference On
, which is controlled by the drive sequencer, indicates that the reference from the
reference system is active.
87
Motor Rpm
RO
Num
ND
NC
PT
FI
OL
Ú
±33000.0 rpm*
Ö
RFC-A
88
Current Magnitude
RO
Num
ND
NC
PT
FI
OL
Ú
0 to Drive Maximum Current A
Ö
RFC-A
89
Torque Producing Current
RO
Num
ND
NC
PT
FI
OL
Ú
± Drive Maximum Current A
Ö
RFC-A
90
Digital I/O Read Word
RO
Bin
ND
NC
PT
OL
Ú
0 to 2047
Ö
RFC-A
91
Reference On
RO
Bit
ND
NC
PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A