Press
at any time to exit from the Model information.
Flow Control Modes
This instrument can operate in several process control modes including:
•
Local (manual) mode
•
Loop mode
•
Tune mode (only available in calibration set mode)
•
Ratio mode
•
Blend-1 mode (for blending point after main flowmeter)
•
Blend-2 mode (for blending point after main flowmeter)
In all of these modes, except Blend-2, the Net flow is the combination of the
Main and Process flows. In Blend-2 the Main flow equals the Net flow.
16-15
EDITED 27/08
2019
The time and date when the calibration of the
instrument was last edited. The format of the time and
date is the same as for the data logs. This example
shows 16:15 (4:15pm) on the 27th August 2019.
This function is available only if the instrument has
the real time clock option.
CLASS-3
FLASH V-019
The instrument Class and Flash (bootloader) version.
5
POWER CYCLE
The number of power cycles that have occurred since
the application software was installed.
1
WDT RESET
The number of ‘watchdog timer’ (WDT) resets that
have occurred since the application software was
installed. The WDT Reset count is only shown if a
WDT Reset has occurred.
HOLD.RST
CONFIG PRINT
If the printer protocol is assigned to one of the
communication ports, the prompt to print the full
program configuration report will be shown. Hold
Reset to start the printing of the configuration report.
The report will be in a similar format to the report
generated by the 500 Program Manager.
Description
DISPLAY
SET