![Contrec 515 BR03 Operation Manual Download Page 25](http://html1.mh-extra.com/html/contrec/515-br03/515-br03_operation-manual_2658193025.webp)
Installation & Maintenance
515 BR03 - 15 August 2021
15
Figure 7 Output 4-20 mA Connection Diagram
Digital Output Connection
Figure 8 shows a connection example for a pulse output. Output channel 1
uses terminals 27 (+) and 28 (-). Output channel 2 uses terminals 29 (+) and
30 (-).
Figure 8 Output Pulse Connection Diagram
18
+
-
DC supply
9-24V
Load
Shield
515
4-20 mA
Output
(OUTn)
+
-
External Load
Resistor 10K
Vo +8...24V DC
15
Logic Input
Open
DC Ground
Collector
Output
16
Pulse Output
(OUTn)
Shield
18
500