background image

 

Maintenance

   

 

 

 

 

 

 

 

33

 

 

 

About scanner maintenance 

Scanner maintenance will ensure the best performance of your scanner.  There are three basic maintenance tasks. 

 

Cleaning 

This section describes how to thoroughly clean the internal scan area. How often you need to clean will depend on how often and the types of media you 
scan. If your work primarily involves scanning newspapers and old blueprints you may need to clean more often than users who only scan brochures and 
new drawings. Be sure to clean the scanner when results start to degrade. Particles of dust in the scan area can sometimes be the sole cause of streaks in 
the end result. See more under the section 

Cleaning the scan area

 

 

Calibration 

 

Calibrate the scanner if your output is degraded but cleaning (above) has not solved the problem. Calibration will renew the original colors and precision of 
BW work. Scanner calibration is started by inserting the calibration sheet and starting the scanner maintenance program. It is extremely important to make 
sure the scanner is clean before calibrating. See more under the section  

Calibration Scanner Maintenance program

. 

 

Replacing the glass plate 

This should be carried out when a worn glass plate starts to affect scanned output. You may need a new glass plate if streaks still appear on the image even 
after cleaning the glass. See more under the section 

Replacing the glass plate

. 

Cleaning the scan area 

How often you clean your scanner will depend on how much you use the scanner and the condition of the documents. As a guide clean the scanner at least once 
a month and always before important jobs that require a high precision.  
 

Clean the following scanner parts or areas:  
 

 

The scanner bed or feed tray area 

 

Glass plate 

 

Upper precision rollers 

 

Lower pressure rollers 

 

Lower rubber transport rollers 

 

NOTE: 

To help locate these parts on the scanner, see the 

Overview of key maintenance points and cleaning

  on the next page. 

Summary of Contents for IQ Quattro X 3600

Page 1: ...User Guide Wide Format Scanner Models IQ Quattro X Series UG14405 1D EN IQQ X AUG 2020...

Page 2: ...to replace the scanner glass plate 47 Downloading New Firmware 53 What is Firmware 53 When do I need new firmware 53 Identifying scanner firmware 53 Installing new firmware 53 Trouble shooting 54 Scan...

Page 3: ...NOTE Different sizes of scanner use many standard parts and the number of catches and rollers varies according to model Illustrations used in this guide are generic and may not always match the scann...

Page 4: ...Optical resolution 1200x1200 dpi interpolation to 9600 dpi Media thickness mm inches 2 0 08 flexible documents only Accuracy 0 1 1 pixel Optical sensing with LED illumination CIS dual illumination Pa...

Page 5: ...sertion slot for document feeding Keypad Magnetic paper guides Paper return guides Paper forward button Power button and tri color LED Ready green Standby yellow Red service or alert Paper backwards b...

Page 6: ...Overview 6 Rear view Connection panel Release buttons for opening scanner lid for maintenance Paper return guides USB 3 0 socket Mains power Connection socket Main power switch I 0 Gigabit socket...

Page 7: ...supplied with your scanner Scanning software or compatible third party software Grounded power outlet PC with USB 3 0 port or enabled Gigabit port NOTE Gigabit interface compatibility and speeds depe...

Page 8: ...rivers Reboot the PC when requested Remove the USB drive when the installation completes After successful installation the WIDEsystem icon will display in the pc system tray Now install the scan and c...

Page 9: ...The internal scan area should be wiped clean for any dust accumulated during packaging and shipping The scan area is under the scanner lid so you have to open it The lid release buttons are at the bac...

Page 10: ...the scanner lid all the way back Clean the internal scan area Wipe the internal scan area free of dust Use a dry lint free cloth If you detect smudges on the glass that cannot be wiped clean with a d...

Page 11: ...r Connect power to the wall outlet Connect the other end of the scanner power cable to the power outlet CAUTION The scanner is equipped with a three wire pin grounding type plug If you cannot insert t...

Page 12: ...w the back of the scanner Connect the B connector end of the cable to the USB 3 0 port on the scanner shown right NOTE For Gigabit enabled scanner models The installation wizard will instruct you on i...

Page 13: ...ack of the PC as front ports can sometimes cause speed problems The Installation Wizard starts up The driver will detect the scanner and start the scanner installation wizard On first time installatio...

Page 14: ...t when done IMPORTANT During the installation always allow the software to access the internet if Windows asks your permission Set the Energy Star idle time The scanner is factory set for automatic en...

Page 15: ...al activation needs a license key and an activation code Activation codes can be obtained from your dealer or from the manufacturer Licensing website Follow the instructions Manual Activation below to...

Page 16: ...you choose Online as the activation method the dialog shown on the top right appears Enter your license key in the designated field A green tick will appear after the authentication check if the licen...

Page 17: ...d Write down or copy the hardware ID displayed by the wizard 1 You will need to transfer both of these to the online activation form Go to www licenseactivate com In the License Activation web form en...

Page 18: ...and glass as instructed in the previous installation steps do so now You will be asked to insert the calibration sheet that came with the scanner Be sure to align the sheet arrow with the scanner mid...

Page 19: ...Installation 19 Installation complete The scanner has been installed correctly when you see this message NOTE Scanner connected using USB 3 0 19...

Page 20: ...ick or right click the WIDEsystem icon to start WIDEsystem Click the refresh button in case an unknown scanner is on the network The interface will display No scanners found Click the Network tab Sele...

Page 21: ...computer installations may prevent or block WIDEsystem from locating the scanner If you think this might be happening ask your IT administrator to check the firewall settings on the computer being use...

Page 22: ...n highlighted in blue Select the scanner Click Next WIDEsystem confirms connection and displays the scanner serial number Click Finish NOTE Scanners already installed on the same network will appear g...

Page 23: ...list can be removed using WIDEsystem Double click or right click the WIDEsystem icon Click the Network tab Click the Remove button Choose the network scanner to remove Click OK to remove it NOTE If a...

Page 24: ...the menu Ensure the WIDEsystem icon is yellow which indicates the scanner is connected Select the Network tab Click the Scanner Setup button The scanner setup window has options to change the scanner...

Page 25: ...or ON and 0 for OFF Self test procedure When you turn the main power ON the scanner will run a short self test that takes less than a minute The LEDs on the panel will light during the self test All L...

Page 26: ...scanner operation The scanner will go from Wake mode into Sleep mode Automatically After a set idle time see Sleep mode options below Manually When you hold the power button down for 3 seconds Hold d...

Page 27: ...double click the WIDEsystem icon in the system tray Select the Timer Tab If you want to put the scanner into sleep mode before the time set in this option use the manual method for entering sleep mode...

Page 28: ...Automatic loading With automatic loading the scanner takes the original as soon as you insert it in the paper slot Automatic loading is reliable for most jobs and especially useful for batch scanning...

Page 29: ...d the Paper Loaded LED lights up green While holding the original in place with one hand use the other hand to press and hold down the Paper Forward button on the scanner When the Paper Loaded LED tur...

Page 30: ...nning software input size dialogue defines the area to be scanned NOTE The exact choice of input size options will depend on your scanning software and its compatibility with the scanner There are at...

Page 31: ...scan a whole set of originals that require equal scan settings The basic steps are Set your scan settings size type image adjustments for the batch Your settings will apply to ALL the documents in the...

Page 32: ...pening the Info tab Install new firmware by downloading new firmware to a folder on the connected computer Right click the scanner icon and select Advanced Options Update Scanner Firmware Reset the co...

Page 33: ...canner calibration is started by inserting the calibration sheet and starting the scanner maintenance program It is extremely important to make sure the scanner is clean before calibrating See more un...

Page 34: ...the key parts and areas inside important for cleaning The number of rollers and lid release catches will be different for different sizes of scanner Lower rubber transport rollers Lower pressure roll...

Page 35: ...s the main power switch at the back of the scanner to the OFF position 0 Disconnect the scanner power plug CAUTION Always disconnect power before cleaning the scanner This is to ensure your own person...

Page 36: ...canning Open the scanner lid by sliding the lid release latches Next open the scanner lid using the release latches at the back of the lid Stand at the front of the scanner Push down on the lid while...

Page 37: ...lean lint free cloths for cleaning the glass plate Do not reuse the cloth you used to wipe the scanner bed Spray apply a mild streak free glass cleaner onto a lint free cloth Gently wipe the glass cle...

Page 38: ...free cloth Make sure that you leave the area dry CAUTION Do not spray apply cleaner fluids directly onto the rollers or anywhere else in the scan area Clean the white pressure rollers The long white r...

Page 39: ...ch roller Use the cloth to turn the rollers so you wipe all sides Dry the transport rollers completely using another clean dry lint free cloth Make sure that you leave the area dry CAUTION Do not spra...

Page 40: ...aintenance 40 Your scanner is now clean You have completed the steps required for cleaning your scanner and the scan area Replace the rear paper guides and two paper tray magnetic guides as required 1...

Page 41: ...t is very important that the scanner feed area and glass are completely clean before calibrating To calibrate your scanner Turn the scanner power ON If the main power is OFF press the main power switc...

Page 42: ...ray to open the WIDEsystem program Press the Calibrate button Calibration Choose the calibration Select either camera alignment or full calibration Camera alignment will align horizontal capture for c...

Page 43: ...sert the calibration sheet The software wizard will ask you to insert the calibration sheet that came with your scanner NOTE The printed side of the sheet must be inserted face up into the scanner arr...

Page 44: ...ation sheet will be rescanned a number of times as the program processes data Let the program complete the calibration steps you requested Alignment or Complete The wizard will tell you when the proce...

Page 45: ...this happens a replacement glass should be fitted to restore peak scanner performance To replace a worn glass plate Turn the main power to OFF Press the main power switch at the back of the scanner to...

Page 46: ...he lid while at the same time sliding both release latches towards the center of the scanner until you feel them unlock Use your other fingers to grip the edge of the lid Open the scanner lid Keeping...

Page 47: ...plate The glass plate is locked in place by several white latches Press down the latch release buttons to release the glass plate see below The number of latches will be different for different sizes...

Page 48: ...e see arrow press down on the latch release button visible in the small square hole Using the tip of the tool pop the edge of the glass upwards until it s free of the white latch Let go of the latch r...

Page 49: ...ddle area Tip the glass back and up so the two ends are free NOTE Use the flat tool again if you cannot get your thumbs underneath Lifting out the glass plate Move your hands one at a time to each end...

Page 50: ...nderside Hold the glass so the underside faces down and at an angle towards your body as shown Maintaining the angle carefully lower the glass into the groove nearest the back of the upturned scanner...

Page 51: ...s in the two rear and front position grooves Lock the glass in place Hold down the latch release button nearest to the scanner keypad Press down on the glass near to the latch and click it into place...

Page 52: ...uid gets under the glass Leave the area dry CAUTION Do not spray apply cleaner fluids directly on the glass plate or anywhere else in the scan area Close the scanner From the nearest edge lift the sca...

Page 53: ...upgrade will be included in the release firmware notes Identifying scanner firmware Start WIDEsystem and double click its icon Select the Info tab to view the following Firmware release the installed...

Page 54: ...l error information or Look for a description of the error and remedy in the trouble shooting section of this guide Technical assistance You should contact your service provider if one or more of the...

Page 55: ...oting Shut down the scanner and PC and unplug the power and USB connections Then plug in the USB 3 0 connections and turn on the PC When Windows is ready plug in the scanner power and turn on the scan...

Page 56: ...tact your dealer to obtain the correct WIDEsystem version WIDEsystem drivers were not installed before connecting the scanner Shut down the scanner and PC unplug the connections and restart the instal...

Page 57: ...user guide and follow the instructions provided In some cases you may need to contact your service provider for technical assistance if one or more of the following is true The error cannot be remedie...

Page 58: ...er Backwards or the Paper Forward key to eject the document from the scanner If the document cannot be ejected using the keypad remove it after opening the scanner lid see lid open instructions Releas...

Page 59: ...se objects can disrupt scanner calibration triggering an error Call your technical service provider if the problem persists Scanner will not connect or cannot be operated after a failed firmware upgra...

Page 60: ...need adjustment Request assistance from your technical service provider Thin vertical lines showing in the paper direction of image not seen in the original Clean the scanner glass and rollers as desc...

Page 61: ...ts or openings in the cabinet at the back or bottom are provided for ventilation This ensures reliable operation of the product and protects it from overheating These openings must not be blocked or c...

Page 62: ...facturer may cause harmful interference and void the user s authority to operate the equipment CE Regulations EU This equipment has been tested and found to comply with the limits for a Class A produc...

Page 63: ...d and High Adjustable Stand working heights Scanner Model Low Adjustable Stand mm inches High Adjustable Stand mm inches low med high h1 h2 h3 h4 h5 h6 h7 h8 h9 IQ Quattro X 3600 Series MV52D 827 32 6...

Page 64: ...Appendix 64 Low Adjustable Stand NOTE Drawing shows stand 44 at its lowest working height setting of 827 dimensions in mm...

Page 65: ...Appendix 65 High Adjustable Stand NOTE Drawing shows stand 44 at its highest working height setting of 1292 dimensions in mm...

Page 66: ...agen Denmark Phone 45 4814 1122 info contex com Contex Americas Global Scanning Americas MD Inc Chantilly VA 20151 USA Phone 1 703 964 9850 salesamericas contex com Contex Japan Asia Global Scanning J...