69
Fault elimination
Code
Message
Information
Warning
Error
Possible causes
Remedy
–––
E97
External
24V Supply
External 24 V supply faulty. Voltage too high or too low.
Fuse "F2" on the driver board defec-
tive.
Contact your Condair representative.
Short circuit on external connection.
Overload on external connection.
–––
E98
External
10V Supply
External 10 V supply faulty. Voltage too high or too low.
Fuse "F2" on the driver board defec-
tive.
Contact your Condair representative.
Short circuit on external connection.
Overload on external connection.
–––
E100
Y1
Fault on Inlet valve Y1.
Inlet valve not connected or coil
defective.
Contact your Condair representative.
–––
E103
to
E107
Yx
(e.g., Y5)
Fault on corresponding spray valve (Y5 to Y9).
Spray valve not connected or coil de-
fective.
Contact your Condair representative.
–––
E110
Y10
Fault on drain valve Y10.
Drain valve not connected or coil de-
fective
Contact your Condair representative.
–––
E111
Y4
Fault on external optional water supply flushing valve Y4.
Water supply flushing valve not con-
nected or coil defective
Contact your Condair representative.
–––
E113
Y3
Fault on optional air cleaing valve Y3.
Air cleaing valve not connected or coil
defective
Contact your Condair representative.
–––
E118
Water Temperature
Temperature of the supply water from the reverse osmosis system has exceeded
the max. limit value. Humidification is stopped.
Ambient temperature in the area of the
central unit too high.
Ventilate/cool the room.
Supply water temperature too high.
Check water system.
Water temperature sensor defective.
Contact your Condair representative.
Water temperature sensor not or not
correctly connected.
–––
E153
Y11
Fault on optional auxiliary outlet valve Y11.
Auxiliary outlet valve not connected
or coil defective.
Contact your Condair representative.
W157
–––
Software download
from USB failed
Software download from USB failed.
Connection aborted during software
download from USB stick or faulty
update file.
Contact your Condair representative.
W158
–––
Software download
from Cloud failed
Software download from Cloud failed.
Connection aborted during software
download from Cloud or faulty update
file.
Contact your Condair representative.
–––
E162
Software update
failed
Software update failed.
Integrated controller switched off
during update process or invalid
software version downloaded.
Contact your Condair representative.
Summary of Contents for DL II
Page 79: ......