It is possible to switch back to the other delivery regulator and change its pressure by pushing the Output Source PB again.
The delivery pressure for both regulators should be the same to within 1-2 PSI for best performance.
20.
Locate SW5 on the control board (Figure 29) and press it once. The system should go back to normal operation showing
inlet pressures on both inlet displays.
Figure 29
21.
Repair is complete. Close door and re-attach screws.