Test 6 – Auxiliary Settings
Displays settings for Units of Measure, Communication
setting, Keypad lockout, allow remote settings enable,
Auxiliary Gas source enable.
Refer to Table 9 to determine what is enabled
Test 7 – Delivery Regulator Pressure Tolerance
This number represents the value added or subtracted to the
nominal delivery pressure of the product. It is used to
determine the allowable range of operation before a delivery
regulator fault condition is declared.
Test 8 – Look Back Time
This value is the number of minutes the system waits before
looking back.
Test 9 – Switch Back Time
This is the value, in minutes, used by the system to determine
when a cylinder is truly empty and incapable of supplying
sufficient gas.
Test 10 – Hysteresis
This is a pressure value used to prevent the system from
inadvertently switching back and forth between inlet sides
unnecessarily.