5-6
I
Maintenance
Removing the Pump Motor and Seal
(1/2 to 2 Hp, any frequency and 3 HP, 60 Hz units)
(Continued)
8
Slide the rotating half of the shaft seal off of the shaft
. Be careful not to contami-
nate, chip, or scratch seal surfaces if it is to be re-used. Set seal half aside for re-use
if appropriate.
9
Using a 9/16-inch wrench, remove the four (4) casing bolts.
10
Slide motor adapter off of motor shaft.
11
Press stationary half of
pump seal out of motor
adapter, being careful
not to damage rubber
diametral seal or rotating/
non-rotating seal inter-
face surface. Set seal half
aside for re-use if appro-
priate.