O
PERATION
4-17
UGE059/1003
SC-5 SURE CUT Servo Knife Cutter
Next, Pressing Next selects the DevCC test if available. If the
arrow on the top right hand side of the screen is visible the
current mode also supports the DevCC test.
The DevCC repeatability tester also displays total deviation
time in milliseconds. This time is from a cut being
requested until the next cut request. The smallest measured
value is subtracted from the largest measured value and the
resulting deviation is displayed on the screen. The DevCC
repeatability test is available in some on-demand modes, and
all continuous modes. This test is used as a tool for verifying
the accuracy of the upstream puller or the precision timer
option.
On/Off Softkey1
On the display, on the lower left side is a soft key labeled On
or Off. Pressing this key while On is displayed will reset all
values and disable testing. Likewise pressing this key while
Off is displayed starts the test.
Reset Softkey3
On the display, on the lower right side is a soft key labeled
Reset. Pressing this key will reset all test values and start a
new test.
Exit, Pressing Exit or the Softkey under the word Exit resets
all values, disables testing then returns the display to the
Function area screen.
Prev, Pressing Prev selects the DevCP test if available. If the
arrow on the top left hand side of the screen is visible the cur-
rent mode also supports the DevCP test.
NOTE: The test available DevCP, DevCC or both is
dependent on the active cut mode.
< DevCC 000.000 mS
Off
Exit
Reset
NOTE: The test available DevCP, DevCC or both is
dependent on the active cut mode.
C
ONTROL
I
NSTRUCTIONS
T
EST
CONTINUED