XSAT7080 X-Band Transceiver
Revision 0
Redundant Systems
MN/XSAT7080.IOM
5-3
5.2 RSU-5060 I
NTERFACES
5.2.1 E
LECTRICAL
I
NTERFACE
The RSU-5060 contains five primary electrical control interface connectors, (J1 through J5) and
six IF signal connectors (J6 through J11) .
Table 5-1. RSU-5060 Interface Connectors, without IF Transfer Switches
Connector
Function
Connector Type
J1
XSAT Unit A interface
MS3112E14-19S
J2
Rx Waveguide Switch interface
MS3112E10-6S
J3
XSAT Unit B interface
MS3112E14-19S
J4
Tx Waveguide Switch interface
MS3112E10-6S
J5
Customer M&C interface
MS3112E14-19S
J6
Tx IF Input from Customer Equipment Type N, Female
J7
Tx IF Output to XSAT A
Type N, Female
J8
Tx IF Output to XSAT B
Type N, Female
J9
Rx IF Output to Customer Equipment
Type N, Female
J10
Rx IF Input from XSAT A
Type N, Female
J11
Rx IF Input from XSAT B
Type N, Female
Table 5-2. RSU-5060 Interface Connectors, with IF Transfer Switches
Connector
Function
Connector Type
J1
XSAT Unit A interface
MS3112E14-19S
J2
Rx Waveguide Switch interface
MS3112E10-6S
J3
XSAT Unit B interface
MS3112E14-19S
J4
Tx Waveguide Switch interface
MS3112E10-6S
J5
Customer M&C interface
MS3112E14-19S
J6
Tx IF Input from Customer Equipment Type N, Female
J7
Tx IF Sample
Type N, Female
J7
Tx IF Output to XSAT A
Type N, Female
J8
Tx IF Output to XSAT B
Type N, Female
J9
Rx IF Output to Customer Equipment
Type N, Female
J9
Rx IF Sample
Type N, Female
J10
Rx IF Input from XSAT A
Type N, Female
J11
Rx IF Input from XSAT B
Type N, Female