XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-9
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Rx Slope
Adjust
DSA=
3 bytes
Command or Query.
Rx Slope Adjust, between 0.0 and 1.0.
Resolution = 0.1.
Example: DSA=0.3
DSA= (message ok)
DSA? (received ok,
but invalid arg.
found)
DSA? DSA=
x.x
(same format as command
argument)
Reference
Oscillator
Adjust
REF=
3 bytes
Command or Query.
Ref Osc Adjust, between 000 and 255.
Resolution 001.
Example: REF=087
Note: REF cannot be adjusted when the XSAT
is locked to an external reference source.
REF= (message ok)
REF? (received ok,
but invalid argument
found)
REF* (message ok,
but not permitted in
current mode)
REF? REF=
xxx
(same format as command
argument)
Cold Start
CLD=
1 byte,
value of 0,1
Command or Query.
Cold Start, where:
0 = Disabled,
1 = Enabled
Example: CLD=1
CLD= (message ok)
CLD? (received ok,
but invalid
arguments found)
CLD?
CLD=
x
(same format as command
arguments)
Auto Fault
Recovery
AFR= 1
byte,
value of 0,1
Command or Query.
Auto Fault Recovery, where:
0 = Disabled,
1 = Enabled
Example: AFR=1
AFR= (message ok)
AFR? (received ok,
but invalid
arguments found)
AFR?
AFR=
x
(same format as command
arguments)
Online
Status
N/A 1
byte,
value of 0,1
Query Only.
Online status, where:
0 = OFFLINE,
1 = ONLINE
Example: ONL=1
ONL= (message ok)
ONL? (received ok,
but invalid
arguments found)
ONL?
ONL=
x
(same format as command
arguments)
LNA Current
Source
LCS= 1
byte,
value of 0,1
Command or Query.
LNA Current Source, where:
0 = Disabled,
1 = Enabled
Example: LCS=1
LCS= (message ok)
LCS? (received ok,
but invalid
arguments found)
LCS?
LCS=
x
(same format as command