XSAT7080 X-Band Transceiver
Revision 0
5-25W Installation
MN/XSAT7080.IOM
A–19
A.5.3 C
ONNECT
C
ABLING TO THE
R
EMOTE
S
WITCH
B
OX
, AS/0490
USING
AS/0440 C
ABLE
K
IT
Note:
Refer to Figure A-18a for assembled view, refer to Figure A-21for LNA port
locations, and refer to Figure A-12 for Cable kit.
Step
Procedure
1
Connect one end of the Control cable, (4, Figure A-12) to UNIT A
(1, Figure A-17) connector.
2
Connect one end of the Control cable, (5) to UNIT B (2, Figure A-17)
connector.
3
Connect one end of Cable (2) to RX SWITCH (3 , Figure A-17) connector.
4
Connect one end of Cable (3, figure A-13) to TX SWITCH connector (4 ,
Figure A-17). Set box aside for later installation.
5
The four RF cables, (1, Figure A-12) are used to connect the IF ports on the
switch controller to the units.
Figure A-17. Remote Switch Cast Box
Figure A-18a. Switch Box with Cables