XSAT7080 X-Band Transceiver
Revision 0
Theory of Operation
MN/XSAT7080.IOM
6–3
6.1.2 U
PCONVERTER
The RF input to the upconverter is at 70
±
18 MHz at a typical level of -35 dBm which would
provide an output power back-off of 8 dB. In operation, the input signal is mixed up to the 1350
MHz IF in the first conversion mixer operating at a fixed frequency with low side LO injection at
1280 MHz provided by the upconverter IFLO. IF filtering is provided by the 1350 MHz BPF. It is
just wide enough to pass the 36 MHz bandwidth of the desired signal while maintaining more
than adequate amplitude and group delay flatness. At the same time, it is narrow enough to
provide the necessary rejection to any unwanted mixer products, the IFLO, and other spurious
signals.
The second mixer up converts the 1350 MHz IF signal to the desired output frequency. It uses
low side LO injection in the 6550 to 7050 MHz frequency range provided by the upconverter
RFLO in 1.000 or 2.500 MHz steps. Both step sizes are automatically selectable. The
upconverted signal is then filtered to reject the RFLO leakage, and any other unwanted mixer
spurs at the mixer output. The output signal is then amplified by a series of internally matched
power FET's to raise the power level of the output signal to the specified level. An isolator is
provided at the output of the high power output stage to protect it from mismatches at the output
connection to the antenna feed.
Figure 6-2. Functional Block Diagram of the Upconverter Section