SLM-5650 Satellite Modem
Revision
1
Remote Control
MN/SLM5650.IOM
B–19
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx
Reacquisition
Time
REA=
3 bytes
Command or Query.
Rx reacquisition time, in Seconds, ranging from 0 to 999.
Example: RSW=000 (selects 0 seconds)
REA=
REA?
REA*
REA#
REA?
REA=xxx
(see description of
arguments)
Rx Clock
Source
RCK=
1 byte, value
of 0 thru 2
Command or Query.
Rx Clock Source , where:
x=Rx Clock Source, where:
0=Rx Satellite
1=Internal
2=Tx-Terrestrial
3=External Clock (only valid with the G.703 Option Card)
Example: RCK=2 (selects Tx-Terrestrial)
RCK=
RCK?
RCK*
RCK#
RCK? RCK=x
(see description of
arguments)
Rx Buffer
Programming
Mode
RBM=
1 byte, value
of 0 or 1
Command or Query.
Rx Buffer Programming Mode, where:
0 = Buffer Size is programmed in Bits.
1 = Buffer Size is programmed in milliseconds.
Example: RBM=0
RBM=
RBM?
RBM*
RBM#
RBM? RBM=x
(see description of
arguments)
Rx Buffer Size
RBS=
8 bytes
Command or Query.
Rx Buffer Size (in either bits or milliseconds, see RBM command),
where:
xxxxxxxx=Rx Buffer Size
Example: RBS=00000512
RBS=
RBS?
RBS*
RBS#
RBS? RBS=xxxxxxxx
(see description of
arguments)
Modem
Reference
Clock
MRC=
1 byte, value
of 0 thru 3
Command or Query.
Modem Reference Clock (For Frequency Accuracy), where:
0=Internal
1=External 1 MHz
2=External 5 MHz
3=External 10 MHz
MRC=
MRC?
MRC*
MRC#
MRC? MRC=x
(see description of
arguments)