SLM-5650 Satellite Modem
Revision 1
Remote Control
MN/SLM5650.IOM
B–32
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Receive T2
Framing
T2F=
1 byte, value
of 0, 1, 3, or 5
Command or Query.
Receive T2 Framing, where:
0=None
1=G.704
3=G.743
5=G.747
Example: T2F=0
T2F=
T2F?
T2F*
T2F#
T2F? T2F=x
(see description of
arguments)
Receive E2
Framing
E2F=
1 byte, value
of 0, 1, 2, or 4
Command or Query.
Receive E2 Framing, where:
0=None
1=G.704
2=G.742
4=G.745
Example: E2F=0
E2F=
E2F?
E2F*
E2F#
E2F? E2F=x
(see description of
arguments)
External
Buffer Clock
Reference
ERF=
1 byte, value
of 0 thru 3
Command or Query.
External Buffer Clock Reference, where:
0=External Clock equals Rx Data Rate
1=5 MHz External Clock
2=10 MHz External Clock
3=20 MHz External Clock
Example: ERF=0
ERF=
ERF?
ERF*
ERF#
ERF? ERF=x
(see description of
arguments)