4.3.3 Select:
Save/Load
Loc
Permits the user to select the location to either save or load a configuration.
There are 10 locations available, 0 – 9.
Action
Permits the user to select either Save or load the selected location. View is the
default setting that allows the user to select the location before loading or
saving. To save a configuration go through the modems menu’s and configure
all the necessary parameters. Then select a location, then select save and
press enter. To load a saved configuration, select the desired configuration,
then select load and press enter.
IMPORTANT
Resetting the modem will cause all configurations to be cleared!
4.3.4 Select:
Utility
RT-
Clk
Permits the user to select and set the Real-Time Clock. Hours are in 24 hour
time format. Date format is day, months and years.
RefAdjust
Permits the user to select and adjust the internal high stability 10 MHz oscillator
to counteract aging. The control value is in hex, not decimal and has a range of
000 to FFF. The typical cal point for a modem is nominally around 400.
ID
Permits the user to give the communications link a name. This name can be a
combination of alpha and numeric characters up to 24 characters in length.
Additional characters supported are: (, ), *, +, /, period, comma and space.
Display
Permits the user to adjust the front panel display brightness. Settings are 25%,
50%, 75% or 100%.
Cal
Permits the user to calibrate the L-Band IF board. This calibration is required
when increasing the data rate beyond 52 Mbps and is
Not
operational at this
time.
Agc
Permits the user to select Minimum and Maximum voltage levels for the
external AGC monitor voltage that is available on the AUX connector.
AudibleAlarm
Permits the user to disable or enable the alarm.
Firmware
Permits the user to select which image will be loaded and view information on
the Boot ROM, Image#1 or Image#2.
FAST
Permits the user to load FAST codes and view the modem serial number plus
the enabled FAST options.
UTILITY: RT-Clk RefAdjust ID Display Cal
Agc AudibleAlarm Firmware FAST
Save/Load: Loc:0 Action: View
Empty (
ef
E)