SLM-5650 Satellite Modem
Revision 1
Remote Control
MN/SLM5650.IOM
B–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Local/Remote
Status
LRS=
1 byte, value
of 0 or 1
Command or Query.
Local/Remote status, where:
0=Local
1=Remote
Example: LRS=1 (which is Remote)
LRS=
LRS?
LRS*
LRS#
LRS? LRS=x
(see description of
arguments)
Software
Revision
N/A
43 bytes
Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form:
Boot:xx.yy.zz Bulk1:xx.yy.zz Bulk2:xx.yy.zz
Example: SWR=Boot:01.01.01 Bulk1:01.01.01 Bulk2:01.01.01
N/A SWR?
SWR=Boot:xx.yy.zz
Bulk1:xx.yy.zz
Bulk2:xx.yy.zz
(see description
of arguments)
Software
Image
IMG=
1 bytes, value
of 1 or 2
Command or Query.
Current Active software image, where:
1 = Bulk Image #1 currently active
2 = Bulk Image #2 currently active
Example: IMG=1 (which is Image #1 active)
IMG=
IMG?
IMG*
IMG#
IMG? IMG=x
(see description of
arguments)
Serial Number
N/A
9 bytes
Query only.
Used to query the unit 9-digit serial number. Unit returns its S/N in
the form xxxxxxxxx.
Example: SNO=176500143
N/A SNO? SNO=xxxxxxxxx
(see description of
arguments)
Temperature
N/A
3 bytes
Query only.
Unit returns the value of the internal temperature, in the form of xxx
(degrees C).
Example: TMP=+26
N/A TMP? TMP=xxx
(see description of
arguments)