SLM-5650 Satellite Modem
Revision 2
Installation
MN/SLM5650.IOM
2–3
2.2.2
Optional Installation Using a Typical Customer Rack
Step
Procedures
1
Mount the modem chassis in the assigned position of the equipment rack.
Support the modem by either a rack-mounted shelf, or the two rear rack-
mounted brackets supplied with the unit.
Note:
For a custom rack installation, refer to the rack drawing in
Figure 2-1. Additional information can be obtained from Comtech EF Data
Customer Support: www.comtechefdata.com
2
Connect the cables to the proper locations on the rear panel.
3
Before turning the power switch on, become familiar with front panel
operation in Chapter 4.
4
Turn on the power switch.
5
Check for the proper transmitter (TX) output signal level and spectrum.
6
Check for proper receiver (RX) input signal level and function.
7
If there is any problem with the installation, refer to Chapter 5 for
troubleshooting information.
Figure 2-2. Typical Customized Rack
Note: Cool air is drawn in on the left side
and hot air is exhausted on the right side.