3–7
3.3.1.5 Ethernet
Interface
Figure 3-5 illustrates the RCS11 that supports 10/100/1000 Data Rates. The RCS11 Ethernet
interface can be configured to support a modem or modulator/demodulator. The S1 switch must
be properly set to the correct position to support the modem or Modulator/Demodulator.
Table 3-5 describes the connection hardware required.
Figure 3-5. RCS11 Ethernet Interface (10/100/1000)
N
O
T
E
:
O
n
t
h
e
S
1
Switch moving the switch to the left sets the unit to the Modem Feature, moving the
switch to the right sets the unit to the Mod/Demod Feature.
NOTE: Power must be cycled after changing S1 to desired setting for effect to take place.
Figure 3-6. RCS11 S1 Switch Diagram
Table 3-5. Connection Hardware
LOCATION
CONNECTOR
DESCRIPTION
J7 DATA A
25-Pin D Sub
EIA 530 Data Primary
J10 TERR DATA
25-Pin D Sub
EIA 530 Data Input
J11 DATA B
25-Pin D Sub
EIA 530 Data Back Up
J27 DATA B
RJ45
Ethernet Data Back Up
J28 TERR DATA
RJ45
Ethernet Data
Input/Output
J29 DATA A
RJ45
Ethernet Data Primary
S1
Switch
Modem or Mod/Demod
setting
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...