RCS11 COMMON CONNECTIONS
5.4.1 FAULTS (J1)
The Fault Port is a 9-Pin Female ‘D’ Connector. This does not include the HSSI interface. Refer
to Table 5-2 for pinouts.
Table 5-2 Fault Port – 9-Pin Female ‘D’ Connector
Pin No.
Description
Status
1
Switch Fault Relay
Common
2
Switch Fault Relay
Normally Open
3
Mod B Selected Relay
Normally Closed
4
Demod B Selected Relay
Common
5
Demod B Selected Relay
Normally Open
6
Switch Fault Relay
Normally Closed
7
Mod B Selected Relay
Common
8
Mod B Selected Relay
Normally Open
9
Demod B Selected Relay
Normally Closed
5.4.2 REMOTE (J2)
The Remote Control Port is a 9-Pin Female ‘D’ Connector. Refer to Table 5-3 for pinouts.
Table 5-3. Remote Port – 9-Pin Female ‘D’ Connector (J2)
Pin Number
Description
Signal
1
*
RS-485 Remote RLLP Select
2 RX
RS232
Input
3 TX
RS232
Output
4 NC
NA
5 Ground
GND
6
RX (A) – RS485
Input
Table 5-1 DC Power
A
-
B Ground
C
+
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...