MN-RCS11 – Revision 9
B–1
Appendix B. RCS11 Remote
Communications
B.1
Host Computer Remote Communications
Control and status messages are conveyed between the RCS11 and the host computer using
packetized message blocks in accordance with a proprietary communications specification. This
communication is handled by the Radyne Link Level Protocol (RLLP), which serves as a protocol
‘wrapper’ for the RM&C data.
Complete information on monitor and control software is contained in the Radyne RLLP
Protocol Reference Guide.
IMPORTANT
For RS485 Remote communication, install CA/3733 gender changer into
the remote port. Gender changes port from RS232 to RS485
B.1.1 Protocol Structure
The Communications Specification (COMMSPEC) defines the interaction of computer resident
Monitor and Control software used in satellite earth station equipment such as Modems,
redundancy switches, multiplexers, and other ancillary support gear. Communication is bi-
directional, and is normally established on one or more full-duplex 9600-baud multi-drop control
buses that conform to EIA Standard RS-485.
Each piece of earth station equipment on a control bus has a unique physical address, which is
assigned during station setup/configuration or prior to shipment. Valid decimal addresses on one
control bus range from 032 through 255 for a total of up to 224 devices per bus. Address 255 of
each control bus is usually reserved for the M&C computer.
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...