RCS11 1:1 Redundancy Switch
Connector Pinouts
MN-RCS11 – Revision 9
5–13
5.7.2.1
Terrestrial Data (J10) M2P Data Interface
The Terrestrial Data (J10) M2P Interface is a 25-Pin Female ‘D’ port. Refer to Table 5-15 for
pinouts.
Table 5-15. J10 Terrestrial Data (M2P Parallel) (25-Pin Female 'D')
Pin No.
Description
Signal
1 OUTCLK
+
Output
14 OUTCLK
-
Output
2 CLK
+
Input
15 CLK
-
Input
3 SYNC
+
Input
16 SYNC
-
Input
4 VALID
+
Input
17 VALID
-
Input
5 D0
+
Input
18 D0
-
Input
6 D1
+
Input
19 D1
-
Input
7 D2
+
Input
20 D2
-
Input
8 D3
+
Input
21 D3
-
Input
9 D4
+
Input
22 D4
-
Input
10 D5
+
Input
23 D5
-
Input
11 D6
+
Input
24 D6
-
Input
12 D7
+
Input
25 D7
-
Input
13 NC
NA
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...