RCS11 1:1 Redundancy Switch
Installation
MN-RCS11 – Revision 9
4–12
4.6.9 DM240XR ASI Data Interface
Figure 4-9 illustrates a 1:1 system using a RCS11 with 70/140 MHz, ASI Data Interface and
optional Offline IF Monitor connected to DM240XR Modulators. Table 4-9 describes the
connection hardware required.
ASI IN
TX OUT
1
2
2
1
1
1
Figure 4-9. RCS11 with ASI Interface and optional Offline IF Monitor connected to
DM240XR Modulators
Table 4-9. Connection Hardware
Item No.
Quantity
Part Number
Discription
1
4
CA/3598-36
3’ BNC to BNC 75 Ohm Coaxial Cable
2
2
CA/3677-1
Alarm Fault Cable