MN-RCS11 – Revision 9
1–1
Chapter 1. INTRODUCTION
1.1 Description
The Radyne RCS11 1:1 Redundancy Switch provides simple backup redundancy protection for
most configurations of the DMD15, DMD20, DMD50 and DMD2050 Satellite Modems as well as
the DM240XR Video Modulator and DD240XR Video Demodulator. The backup functions of the
RCS11 may be performed manually via the front panel or from the Terminal Mode. Refer to
Figure 1-1 for an illustration of the RCS11 1:1 Redundancy Switch Front Panel, Figure 1-2 for the
Interface options of the RCS11 and Figure 1-3 of a RCS11 Fucntional Block Diagram.
The RCS11 redundant 1:1 switch supports various product configurations that require different
setups. The switch can support a modem, modulator or demodulator only applications.
Operating in the Automatic Mode, the RCS11 immediately places a Backup Modem online in the
event of a Primary Online Modem failure. In the Manual Mode, the user may designate the
selected Online Primary Modem from either the Interactive Front Panel or a remote Terminal
Interface.
Figure 1-1. RCS11 1:1 Redundancy Switch Front Panel
1.2 Redundant
Power
Supplies
The RCS11 is equipped with two fully redundant internal power. Each power supply is fully
independent of the other, including their source of AC power and fusing. The RCS11 remains
fully operational as long as either power supply is providing a source of power. The power
supplies are located one on either side of the front of the RCS11 Chassis.
1.3
Front Panel Controls
The Front Panel of the RCS11 provides all of the necessary controls and LED indicators to
provide the operator with online status and backup status of the online and backup Modulators
and deModulators.
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...