MN-RCS11 – Revision 9 

3–1 

Chapter 3. User Interfaces 

3.1 User 

Interfaces 

There are four user Interfaces available for the RCS11.  These are: 
 

 

Front Panel 

 

Remote Port 

 

Terminal 

 

 

3.2 

Front Panel Interface 

Table 3-1.  RCS11 Front Panel Controls and Indicators 

Nomenclature Description

Function 

Power 1 

Indicates PS1 has 
power applied 

LED illuminates Green 
for Power Available 

Power 2 

Indicates PS2 has 
power applied 

LED illuminates Green 
for Power Available 

Fault  

Indicates a Switch 
Fault has occurred 

LED illuminates Red for 
Switch Fault 

Auto (LED) 

Indicates RCS11 is in 
the Auto Mode 

LED illuminates Green 
for Auto Mode 

Manual (LED) 

Indicates the RSC11 
is in the Manual Mode 

LED illuminates Green 
for Manual Mode 

ENABLE (Pushbutton) 

------------------- 

Enables Front Panel 
controls to function 

SELECT AUTO 
(Pushbutton) 

------------------- 

Allows the operator to 
select Automatic Mode 
of operation 

Demodulator Controls and Indicators

 

Online LED 

Indicates which 
Demodulator is 
online: A or B 

LED illuminates green 
for Online 

Fault LED 

The RCS11 has 
received a 
Demodulator fault 

LED illuminates Red for 
Fault 

Summary of Contents for Radyne RCS11

Page 1: ...ANT NOTE The information contained in this document supersedes all previously published information regarding this product This manual is subject to change without prior notice RCS11 1 1 Redundancy Sw...

Page 2: ......

Page 3: ...Alarm Fault Cable name Date July 9 2010 Original Manual Part Number MN RCS11 Rev 9 Errata Number Agile Document ID ER RCS11 EA9 Agile CO Number C12397 Change Specifics This information will be incorpo...

Page 4: ...3 HSSI Interfaces Table 4 3 describes the connection hardware required RX IN TX OUT 1 2 2 2 2 3 3 4 DATA IN OUT Figure 4 3 RCS11 with HSSI G 703 Interface Connected to DMD20 DMD50 or DMD2050 Modems wi...

Page 5: ...DMD50 Modems with 70 140 MHz option utilizing the ASI DVB data Interfaces Table 4 4 describes the connection hardware required Figure 4 4 RCS11 with HSSI ASI Interface Connected to DMD20 DMD50 or DMD...

Page 6: ...odems with HSSI Interfaces Table 4 5 describes the connection hardware required Figure 4 5 RCS11 with HSSI ASI Interface Connected to DMD20 Modems with HSSI Interfaces Table 4 5 Connection Hardware It...

Page 7: ...ights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161 RCS11 1 1 Redundancy Switch Installation and Operation Manual Part Number M...

Page 8: ...This page is intentionally blank...

Page 9: ...to Figure 2 1 2 2 2 2 3 Manual Mode 2 2 2 2 4 Auto Mode 2 2 2 2 5 Power Up Defaults 2 2 2 3 RCS11 Major Assemblies 2 2 2 3 1 Main Switch Board 2 3 2 3 2 Front Panel Board 2 3 2 3 3 Redundant Power Su...

Page 10: ...iversal 4 4 4 6 2 DMD20 or DMD50 Universal with G 703 IBS IDR Interface 4 5 4 6 3 DMD20 or DMD50 with HSSI Interface 4 6 4 6 4 DMD20 or DMD50 ASI DVB with RCS11 ASI HSSI 4 7 4 6 5 DMD20 HSSI 4 8 4 6 6...

Page 11: ...J7 5 9 5 6 2 ASI TERR J10 5 9 5 6 3 DATA B J11 5 9 5 6 4 Alarm A J18 5 9 5 6 5 Alarm B J19 5 10 5 7 DVB Parallel Interfaces 5 10 5 7 1 Data A Data B DVB Parallel Interface J7 5 10 5 7 1 1 Data A Data...

Page 12: ...30 J10 5 22 5 10 2 Ethernet Interface 5 23 5 10 2 1 DATA B J27 5 23 5 10 2 2 TERR DATA J28 5 23 5 10 2 3 DATA A J29 5 23 5 10 2 4 SWITCH S1 5 23 5 11 SERIAL INTERFACE 5 23 5 11 1 TERRESTRIAL RS449 RS4...

Page 13: ...H CONFIGURATION A 1 APPENDIX B RCS11 REMOTE COMMUNICATIONS B 1 B 1 Host Computer Remote Communications B 1 B 1 1 Protocol Structure B 1 B 1 2 Protocol Wrapper B 2 B 1 3 Frame Description and Bus Hands...

Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...

Page 15: ...content and design of this manual are appreciated To submit comments please contact the Comtech EF Data Technical Publications department TechnicalPublications comtechefdata com Conventions and Refere...

Page 16: ...dicates a statement associated with the task being performed or information critical for proper equipment function CAUTION CAUTION indicates a hazardous situation that if not avoided may result in min...

Page 17: ...ation as defined in EN60950 Low Voltage Directive LVD The following information is applicable for the European Low Voltage Directive EN60950 HAR Type of power cord required for use in the European Com...

Page 18: ...ech EF Data Corporation s obligations under this warranty are limited to repair or replacement of failed parts and the return shipment to the buyer of the repaired or replaced parts Limitations of War...

Page 19: ...tated is in lieu of all other warranties expressed implied or statutory including those of merchantability and fitness for a particular purpose The buyer shall pass on to any purchaser lessee or other...

Page 20: ...er serial number and a description of the problem Request a Return Material Authorization RMA number from the Comtech EF Data Customer Support representative Pack the product in its original shipping...

Page 21: ...only applications Operating in the Automatic Mode the RCS11 immediately places a Backup Modem online in the event of a Primary Online Modem failure In the Manual Mode the user may designate the selec...

Page 22: ...onfiguration into nonvolatile memory If the power source was then to fail and be restored the RCS11 would again power up in the Auto Mode with both the Modulator and Demodulator set to Modem B Univers...

Page 23: ...CS11 Revision 9 1 3 Optional HSSI and G703 or ASI Interface used with DM240XR DD240XR DMD20 DMD50 Optional Ethernet Interface used with DM240XR DD240XR DMD20 50 Optional T3 E3 Interface used with DMD5...

Page 24: ...RCS11 1 1 Redundancy Switch Introduction MN RCS11 Revision 9 1 4 Figure 1 3 RCS11 Functional Block Diagram...

Page 25: ...require minimal operator intervention and control during normal operation After initial setup the unit should operate in a relatively transparent manner providing trouble free backup of the online Mo...

Page 26: ...ult signals until placed back into Auto Mode 2 2 4 Auto Mode To enable automatic backup in the event of a MOD or DEMOD failure the RCS11 must be placed into the Auto Mode First select which MOD and DE...

Page 27: ...The 1 1 Switch comes equipped with two fully redundant internal power supplies PS1 and PS2 that supplies power to the system Each supply is fully independent of the other including their source of AC...

Page 28: ...ay switches to a faulted state If Power Supply 1 and Power Supply 2 simultaneously fail the switching circuitry in the RCS11 reverts back to Modem A and the Switch Fault Relay switches to a faulted st...

Page 29: ...n for Power Available Fault Indicates a Switch Fault has occurred LED illuminates Red for Switch Fault Auto LED Indicates RCS11 is in the Auto Mode LED illuminates Green for Auto Mode Manual LED Indic...

Page 30: ...eived a fault from Modulator A or B LED illuminates Red for Fault SELECT Mod A or B Pushbutton Allows the operator to select a Modulator A or B 3 3 Rear Panel Interface 3 3 1 System Installation and C...

Page 31: ...J1 FAULT 9 Pin F D Sub Switch Fault Status J2 REMOTE 9 Pin F D Sub 232 or 485 Communications J3 TX B BNC IF Transmit Input From Primary Device J4 TX Out BNC Main IF Output J5 TX A BNC IF Transmit Inp...

Page 32: ...Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 DATA A BNC Asynchronous Data from Primary Device J10 ASI TERR BNC Asynchronous Data Out J11 DATA B BNC Asynchronous Data from Back Up Device J18 A...

Page 33: ...ction hardware required Figure 3 3 RCS11 DVB Parallel Interface RS422 and LVDS Table 3 3 Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 DATA A 25 Pin F D Sub Parallel RS422 and LVDS Data A J10...

Page 34: ...Interface can be configured from the factory to support ASI Asynchronous Serial Interface Figure 3 4 RCS11 HSSI G 703 Interface Table 3 4 Connection Hardware LOCATION CONNECTOR DESCRIPTION J8 TERR DA...

Page 35: ...100 1000 N O T E O n t h e S 1 Switch moving the switch to the left sets the unit to the Modem Feature moving the switch to the right sets the unit to the Mod Demod Feature NOTE Power must be cycled...

Page 36: ...kup Device J15 ESC 8K Data 15 Pin D Sub Female Eng Service Channel for Teletype J16 ESC Voice 9 Pin D Sub Female Eng Service Channel for Voice or 64k Data J17 ESC Alarms 25 Pin D Sub Female Eng Servic...

Page 37: ...onnection hardware required Figure 3 8 RCS11 RS449 422 Serial Interface Table 3 7 Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 Data A 37 Pin D Sub Data Primary Device J10 Terrestrial Data 37...

Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...

Page 39: ...NG There are no user serviceable parts or configuration settings located inside the RCS11 Chassis There is a potential shock hazard internally at the power supply module DO NOT open the RCS11 Chassis...

Page 40: ...preparation simplifies the installation process and results in a more reliable system The user should ensure that the site has adequate electrical power environmental controls and protection against s...

Page 41: ...intenance and Troubleshooting 4 5 System Connections For initial RCS11 setup and configuration perform the following procedure 1 Verify that the AC Power Cords to the RCS11 and units to be connected a...

Page 42: ...earth protection In addition the IF input and output coax cable shielding must be properly terminated to the Chassis unit ground 4 6 Connections This section provides data and frequency connections i...

Page 43: ...1 system using the RCS11 with the Universal Interface connected to DMD20 Modems with 70 140 MHz IF configuration and G 703 IBS IDR Interfaces Table 4 2 describes the connection hardware required RX I...

Page 44: ...HSSI Interfaces Table 4 3 describes the connection hardware required RX IN TX OUT 1 2 2 2 2 3 3 4 DATA IN OUT Figure 4 3 RCS11 with HSSI G 703 Interface Connected to DMD20 DMD50 or DMD2050 Modems wit...

Page 45: ...DMD50 Modems with 70 140 MHz option utilizing the ASI DVB data Interfaces Table 4 4 describes the connection hardware required Figure 4 4 RCS11 with HSSI ASI Interface Connected to DMD20 DMD50 or DMD...

Page 46: ...dems with HSSI Interfaces Table 4 5 describes the connection hardware required Figure 4 5 RCS11 with HSSI ASI Interface Connected to DMD20 Modems with HSSI Interfaces Table 4 5 Connection Hardware Ite...

Page 47: ...140 MHz and Ethernet Data Interfaces Table 4 6 describes the connection hardware required RX IN DATA IN OUT TX OUT 1 2 2 2 2 3 3 4 4 Figure 4 6 RCS11 with Ethernet Interface Connected to DMD20 Modems...

Page 48: ...D50 or DMD2050 Modems with 70 140 MHz and T3 E3 Interface Table 4 7 describes the connection hardware required Figure 4 7 RCS11 with a E3 T3 STS1 Interface Connected to a DMD50 or DMD2050 Modems with...

Page 49: ...IC Modulators with 70 140 MHz and ASI PIIC Card Table 4 8 describes the connection hardware required Figure 4 8 RCS11 with ASI Interface Connected to DM240 PIIC Modulators with an ASI PIIC Card Table...

Page 50: ...ptional Offline IF Monitor connected to DM240XR Modulators Table 4 9 describes the connection hardware required ASI IN TX OUT 1 2 2 1 1 1 Figure 4 9 RCS11 with ASI Interface and optional Offline IF Mo...

Page 51: ...Demodulators Table 4 10 describes the connection hardware required RX IN 1 2 3 2 3 4 4 DATA OUT Figure 4 10 RCS11 with Ethernet Interface Connected to DD240XR Demodulators Table 4 10 Connection Hardwa...

Page 52: ...t Interface connected to DM240XR Demodulators Table 4 11 describes the connection hardware required Figure 4 11 RCS11 with Ethernet Interface Connected to DM240XR Modulators Table 4 11 Connection Hard...

Page 53: ...modulators with HSSI PIIC Cards Table 4 12 describes the connection hardware required DATA IN TX OUT 1 2 3 1 2 Figure 4 12 RCS11 with HSSI ASI Interface Connected to DM240XR Modulators with HSSI PIIC...

Page 54: ...with DVB M2P Parallel PIIC Cards Table 4 13 describes the connection hardware required DATA IN TX OUT 1 1 2 2 3 3 Figure 4 13 RCS11 with Parallel Interface Connected to DM240XR Modulators With DVB Pa...

Page 55: ...140 MHz IF and HSSI Data Interfaces Table 4 14 describes the connection hardware required Figure 4 14 RCS11 with HSSI ASI Interface connected to DD240XR Demodulators with HSSI Interface Table 4 14 Co...

Page 56: ...ilizing the HSSI Interfaces Table 4 15 describes the connection hardware required Figure 4 15 RCS11 with HSSI ASI Interface Connected to DM240XR Modulators and DD240XR Demodulators with HSSI Interface...

Page 57: ...49 Serial Interface connected to DMD20 s using the EIA 530 connection Table 4 16 describes the connection hardware required Figure 4 16 RCS11 with Serial Interface Connected to DMD20 s Table 4 16 Conn...

Page 58: ...S11 will not pass BUC Voltage Table 4 17 describes the connection hardware required Figure 4 17 RCS11 with Serial Interface Connected to DMD20LBST s Table 4 17 Connection Hardware Item No Quantity Par...

Page 59: ...supplied power cables is 10 240 VAC 50 60 Hz Integrated into each of the power entry module is the Power On Off Rocker Switch Power consumption for the unit is 1A The Power Cord Connector assembly is...

Page 60: ...Mod B Selected Relay Normally Closed 4 Demod B Selected Relay Common 5 Demod B Selected Relay Normally Open 6 Switch Fault Relay Normally Closed 7 Mod B Selected Relay Common 8 Mod B Selected Relay No...

Page 61: ...TX IF input from the modulator If the RCS11 is configured for a 70 or 140 MHz application then this connector is either a 75 Ohm or 50 Ohm BNC connector If the switch is configured for L Band then thi...

Page 62: ...Input 5 5 2 MODEM A B J7 J11 G703 RS422 Serial Universal Interface w SCSI connectors The Modem Channel a Port is a 68 Pin High Density Female SCSI Connector This port is the data interface used to co...

Page 63: ...Output 26 IDR ESC Receive 8 Kbps Clock Input 27 IDR ESC Receive 8 Kbps Data Input 28 IDR ESC Backward Alarm Output 4 Normally Closed 29 IBS Transmit Octet A Output 30 Synch Data Data Mode A Input 31...

Page 64: ...IDR ESC Backward Alarm 4 Normally Open 63 IBS Transmit Octet B Output 64 Synch Data Data Mode B Input 65 Synch Data Clear to Send B Output 66 IBS Receive Octet B Input 67 Synchronous Data Request to...

Page 65: ...or Refer to Table 5 7 for pinouts Table 5 7 J17 ESC ALARMS 25 Pin Female D Pin Description Signal 1 7 Ground GND 2 Backward Alarm Out 1 Normally Open 3 5 9 12 13 24 25 Not Used NA 4 Backward Alarm Out...

Page 66: ...ed Together 3 TXD A Transmit Data A 8 CTS Clear to Send 4 TXD B Transmit Data B 9 NC No Connection 5 GROUND Signal Ground 5 5 7 G 703 Balanced J20 The G 703 Port is a Balanced 15 Pin Female D Connecto...

Page 67: ...ASI serial data for the DM240XR Modulator or DD240XR Demodulator only application 5 6 1 DATA A J7 The Data A is the serial ASI data interface from the modulator or demodulator A This interface is a 7...

Page 68: ...P Parallel RS422 or LVDS protocols The modulators or Demodulators must be configured to support RS422 or LVDS protocol 5 7 1 Data A Data B DVB Parallel Interface J7 The Data A and Data B DVB Parallel...

Page 69: ...interface connects to A or B Modulator or Demodulator Refer to Table 5 13 for pinouts Table 5 13 J7 Data A M2P Parallel 25 Pin Female D Pin No Description Signal 1 OUTCLK Input 14 OUTCLK Input 2 CLK O...

Page 70: ...for pinouts Table 5 14 J10 Terrestrial Data DVB Parallel 25 Pin Female D Pin Description Signal 1 Clock Input 2 15 System Ground GND 3 D7 Input 4 D6 Input 5 D5 Input 6 D4 Input 7 D3 Input 8 D2 Input...

Page 71: ...r pinouts Table 5 15 J10 Terrestrial Data M2P Parallel 25 Pin Female D Pin No Description Signal 1 OUTCLK Output 14 OUTCLK Output 2 CLK Input 15 CLK Input 3 SYNC Input 16 SYNC Input 4 VALID Input 17 V...

Page 72: ...round GND 6 Mod Fault Open Collector Input 5 8 DMD50 UNIVERSAL G703 T3 E3 RS422 SERIAL INTERFACE w SCSI The RCS11 Unversal G703 Unbalanced Synchrounous Interface supports RS422 Serial data and G703 T3...

Page 73: ...supplies the Synchrounous G703 IDR and IBS data information from the modems Refer to Table 5 19 for pinouts Table 5 19 J7 J11 MODEM A 68 Pin Female High Density Connector Pin No Description Signal 1...

Page 74: ...eiver Ready A Input 35 G 703 Send Data B Output 36 Synch Data Send Data Input B Output 37 IDR ESC Backward Alarm 1 Normally Closed 38 G 703 Insert Data Input B Output 39 Synch Data Send Timing B Input...

Page 75: ...A J15 The ESC 8K Data Port is a 15 Pin Female D Connector Refer to Table 5 20 for pinouts Table 5 20 ESC 8K Data Interface 15 Pin Female D Connector J15 Pin No Description Signal 1 Rx Octet B Output 2...

Page 76: ...d GND 2 Backward Alarm Out 1 Normally Open 3 5 9 12 13 24 25 Not Used NA 4 Backward Alarm Out 2 Normally Open 6 Backward Alarm Out 3 Normally Open 8 Backward Alarm Out 4 Normally Open 10 Backward Alar...

Page 77: ...CTS Clear to Send 4 TXD B Transmit Data B 9 NC No Connection 5 GROUND Signal Ground 5 8 7 RXB J30 Modem B RX Data Port SD is a G703 Unbalanced 75 Ohm Female BNC Connector 5 8 8 TERR RX J31 The TERR R...

Page 78: ...ace 50 Pin Connector Pin No Pin No Signal Name Description Direction 1 26 SG Signal Ground 2 27 RT Receive Timing Output 3 28 CA DCE Available Output 4 29 RD Receive Data Output 6 31 ST Send Timing SC...

Page 79: ...or G703 interface 5 9 2 6 RXB ASI or G 703 J20 Modem B RX Data Port SD is an ASI or G703 Unbalanced 75 Ohm Female BNC Connector RCS11 Switch must be ordered supporting either ASI or G703 interface 5 9...

Page 80: ...le 5 26 J36 EIA 530 25 Pin Female D Pin No Signal Name Direction 1 Shield GND 2 Send Data A Input 3 Receive Data A Output 4 Request To Send A Input 5 Clear To Send A Output 6 Data Mode A Output 7 Sign...

Page 81: ...e can be configured to support a modem or Modulator Demodulator The S1 switch must be properly set to the correct position to support the modem or Modulator Demodulator NOTE On the S1 Switch moving th...

Page 82: ...A Input 5 Send Timing A Output 6 Receive Data A Output 7 Request To Send A Input 8 Receive Timing A Output 9 Cllear To Send A Output 11 Data Mode A Output 13 Receive Ready A Output 15 External Clock A...

Page 83: ...O Buffer Output Clock A Output 4 Transmit Data A Output 5 Transmit Clock A Input 6 Receive Data A Input 7 RTS A Output 8 Receive Clock A Input 9 CTS A Input 11 Data Mode A Input 12 DTR A Output 13 Rec...

Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...

Page 85: ...Comtech EF Data Customer Service Department at 480 333 4357 for further information and instructions 6 2 Basic User Checks Upon the detection of an operational failure the source of the failure must...

Page 86: ...oose connections Cables that are suspect should be replaced All jacks on the units have no bent or broken pins Both AC Power Cords are properly plugged into the rear of the RCS11 6 3 Major and Minor F...

Page 87: ...rating parameters can be monitored and controlled via the front panel display keypad or the RS 485 or RS 232 serial control channel in either terminal or command modes The following modem parameters m...

Page 88: ...rsal G703 T3 E3 STS1 HSSI Universal ASI Ethernet 10 100 Base T RS530 7 5 Front Panel LED Indicators Unit Power Supply 1 Power Supply 2 Switch Fault Auto Manual Demodulator Online A B Fault A B Modulat...

Page 89: ...change from an existing interface or configuration to another may require a change to one or more of the DIP switch settings If you are having trouble with DIP switch settings contact Radyne Customer...

Page 90: ...e Port J 20 with the switch in Terminal Mode An empty space in Table A 1 represents the off position Table A 1 Baud Rate Switch Positions BAUD RATE SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8 9600 4800 ON...

Page 91: ...d 82 ON ON ON 83 ON ON ON ON 84 ON ON ON 85 ON ON ON ON 86 ON ON ON ON 87 ON ON ON ON ON 88 ON ON ON 89 ON ON ON ON 90 ON ON ON ON 91 ON ON ON ON ON 92 ON ON ON ON 93 ON ON ON ON ON 94 ON ON ON ON ON...

Page 92: ...tes how to configure the Dip Switches for RS232 Data on an RCS11 with Universal Data Interface Figure A 3 DIP Switch on the RS232 Driver Figure A 4 Illustrates how to configure the Dip Switches for G...

Page 93: ...ions MN RCS11 Revision 9 A 5 Figure A 5 Illustrates standard jumper blocks for fault execution on all Radyne products J4 and JP1 Shunt Blocks should be installed as a factory default configuration J4...

Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...

Page 95: ...ender changes port from RS232 to RS485 B 1 1 Protocol Structure The Communications Specification COMMSPEC defines the interaction of computer resident Monitor and Control software used in satellite ea...

Page 96: ...beginning of a message The SYN character value is always 16h DATA COUNT the 2 Byte Data Count is the number of bytes in the DATA field ranging from 0 through 509 SOURCE ID the Source Identifier define...

Page 97: ...e entire message frame is discarded and the wait for SYN mode goes back into effect If the OPCODE resides within a command message it defines the class of action that denotes an instruction which is s...

Page 98: ...devices slaved to an M C computer the timeout delay parameters may be programmed into the equipment in accordance with site requirements by Radyne Corp prior to shipment or altered by qualified person...

Page 99: ...a to form information packets Each transmitted packet is subject to time out and frame sequence control parameters after which the packet sender waits for the receiver to convey its response Once a re...

Page 100: ...1 byte BYTE COUNT Number of bytes in the DATA field 2 bytes SOURCE ID Identifies the address of the equipment from where the message originated 1 byte DEST ID Identifies the address of the equipment...

Page 101: ...Device Firmware Version LSB binary number implied decimal point 10 Device Firmware Name null terminated string 7 Device Firmware Release Date null terminated string Opcode 2280h Command RCS11 Load Fa...

Page 102: ...Field 8 Bytes 1 Switch Delay Mod Fault MSB 1 Switch Delay Mod Fault LSB 1 Switch Delay Mod NoFault MSB 1 Switch Delay Mod NoFault LSB 1 Switch Delay Demod Fault MSB 1 Switch Delay Demod Fault LSB 1 Sw...

Page 103: ...mware Error Enabled Bit 3 1 Switch NV Alarm Bit 4 1 Switch Internal Alarm Enabled Bit 5 7 unused return 0 2 Spare Current Alarms Always 0 Opcode 2289h Command RCS11 Switch Alarms Masks Command Data Fi...

Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...

Page 105: ...n power up you should receive the following text RCS11 1 1 Redundancy Switch Copyright c 1996 1997 Radyne At the terminal screen you will receive a prompt _ Typing help and pressing Enter will cause t...

Page 106: ...thout additional parameters or miss spelling of the command will return an error message baud Error BAD ARGUMENT staus Error BAD COMMAND Queries Help Status and Ver are typed without addition paramete...

Page 107: ...of ticks that will occur before the RCS11 considers a demod as not faulted If a demod faults and recovers before the demod fault delay then the RCS11 will start counting for the demod non fault delay...

Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...

Page 109: ...3 1 760 x 103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoirdupois Pound Troy Kilogram 1 gram 0 03527 0 032...

Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...

Reviews: