![Comtech EF Data Radyne RCS11 Installation And Operation Manual Download Page 31](http://html1.mh-extra.com/html/comtech-ef-data/radyne-rcs11/radyne-rcs11_installation-and-operation-manual_2648528031.webp)
RCS11 1:1 Redundancy Switch
User Interfaces
MN-RCS11 – Revision 9
3–3
3.3.1.2 ASI
Interface
with
Optional Offline IF Monitor
Figure 3-2 illustrates the RCS11 ASI Interface with the optional offline IF monitor port. This is
used to monitor either the primary or back up data stream when in the offline state. The offline IF
monitor port is available with the ASI Interface only. Table 3-2 describes the connection hardware
required.
Table 3-1. Connection Hardware
LOCATION
CONNECTOR
DESCRIPTION
AC1 / AC2
IEC/EN60320/C/3
Power Entry Module for Primary and
Back Up AC
DC1 / DC2
MS3102A10SC-
3P
Power Entry Module for Primary and
Back Up DC
J1 FAULT
9-Pin F D Sub.
Switch Fault Status
J2 REMOTE
9-Pin F D Sub.
232 or 485 Communications
J3 TX B
BNC
IF Transmit Input From Primary Device
J4 TX Out
BNC
Main IF Output
J5 TX A
BNC
IF Transmit Input From Back Up Device
J7 MODEM A
SCSI
Data and Fault Primary Device
J8 SYNC DATA
37-Pin F D Sub
In and Out Synchronous Data
J11 MODEM B
SCSI
Data and Fault Back Up Device
J15 ECS 8K
DATA
15-Pin F D Sub
Eng. Service Channel for Teletype
J16 ESC VOICE
9-Pin F D Sub.
Eng. Service Channel for Voice or 64K
Data
J17 ESC
ALARMS
25-Pin F D Sub
Eng. Service Channel for Backward
Alarm Reporting
J18 ES/ES
9-Pin F D Sub.
Earth Station To Earth Station
Communication
J20 G.703
15-Pin F D Sub
Balanced Asynchronous Data
J23 SD
BNC
Serial Send Data
J24 DDO
BNC
Drop Data Output
J25 IDI
BNC
Insert Data Input
J26 RD
BNC
Serial Receives Data
Summary of Contents for Radyne RCS11
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...
Page 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...
Page 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...
Page 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...
Page 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...
Page 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...
Page 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...