LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
MN-LPOD
Introduction
Revision 14
1–11
Gain Min (Typical)
70 (75 dB)
Input Power Supply Requirements
90-264 VAC, 47-63 Hz, Power Factor Corrected,
.96 (typical)
(48 VDC optional)
Max IF Input level
(no damage)
+10 dBm
Gain Adjust
20 dB in 0.25 dB steps
Gain Flatness
± 1.5 dB full band (optional ± 2.0 dB full band (-50°
to +55°C))
± 0.30 dB per 40 MHz (optional ± 0.50 dB per 40
MHz (-50° to +55°C)
Gain variation over temp
±1.5 dB max, -40° to +55°C (optional ± 2.0 dB max (-
50° to +55°C))
Input Return Loss
15 dB
Output Return Loss
19.1 dB (1.25:1 VSWR)
Noise Figure
10-15 dB typ, 20 dB max @ min attenuation, (8 dB
typ, 15 dB max PS2 configured as SSPA only)
RF Mute Isolation
-60 dBc min
AM/PM Conversion
2° typ, 3.5° max @ Rated P1dB
Third-order Intermodulation Level
(2 tones, @ -3 dB Total Backoff from P1 dB
(-
6 dBc SCL), Δ 1MHz)
-30 dBc typ, -25 dBc Guaranteed
Spurious Level
Harmonics
-50 dBc @ Prated – 3 dB
Carrier Related In
Band
-60 dBc min @ P1dB
Non-Carrier
Related In Band
-60 dBm max (Input Terminated)
LO Leakage
-25 dBm max
Group delay variation
Linear
± 0.03 ns/MHz
Parabolic
±0 .003 ns/MHz
2
Ripple
± 1.0 ns pk-pk
Data Logging Parameters
Non-Volatile RAM: Capacity 30 days @ 90 minute
intervals. Includes:
•
RF Output Power
•
Mute Status
•
Heatsink Temperature
•
LNB Bias Current