LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
MN-LPOD
Ethernet Interface Operation
Revision 14
4–23
4.5.3.3
Config | Utility
Use this page to configure additional LPOD operating parameters. Click
[Refresh]
to see the latest page data.
Figure 4-15. ‘Config | Utility’ Page
Date and Time
•
Enter a date using international format in the form DD/MM/YY (where
DD = day [01 to 31], MM = month [01 to 12], and YY = year [00 to 99]).
•
Enter a time using HH:MM:SS format (where HH = hour [00 to 23],
MM = minutes [00 to 59], and SS = seconds [00 to 59]).
Click
[Change Date/Time]
to save the changes.
Circuit ID
Enter a Circuit ID (unit identification label) string of up to 48 characters. This is
the identification label for the unit.