LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
MN-LPOD
Ethernet Interface Operation
Revision 14
4–9
See
Figure 4-5
and do these steps:
3.
Enter the Telnet username and password (the default for both
parameters is
comtech
):
4.
The LRS remote command sets or returns Local or Remote state in the
form x, where x=0, 1, 2, or 3:
•
LRS=0 (Local)
•
LRS=1 (Serial)
•
LRS=2 (Ethernet)
•
LRS=3 (Ethernet) (default value)
Use the
LRS=2
remote command to set the remote access parameter for
Ethernet remote control.
Figure 4-5. Telnet Login and Remote Command Execution
You must assign a unique IP Address for each unit on the network
before connecting to an existing network. As the IP address may
need to be changed to something other than the factory default
setting, use the remote command
IPA=xxx.xxx.xxx.xxx.yy
, where:
xxx.xxx.xxx.xxx
is a valid IP address on the network where the unit is
to be installed, and
yy
is the range (typically,
yy
= 24).
Changing the
IPA
value requires that you cycle power on the unit,
and then start a new Telnet session using the new IP address.
See Chapter 5. SERIAL INTERFACE OPERATION
for
more information
about the
LRS
and
IPA
commands.