LGaN
Revision 0
Serial Interface Operation
5–25
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Reboot
RBT=
1 byte
Command only.
Soft Reboot
1 = Reboot System
Example:
<1/RBT=1
RBT =
RBT?
RBT*
N/A
RBT=x
(See
description for
details of
arguments)
Retrieve
Configuration
Status
N/A
Query only.
Used to query the configuration status of the unit.
Where:
AMP = RF power amplifier state
0 = OFF
1 = ON
MUT = RF mute state
0 = un-muted
1 = muted
ONL = Online status for redundancy
ESW = Redundancy state and mode, states:
0 = OFF
1 = ON Tx only
2 = ON Tx & Rx
AOF = Attenuator Offset in dB
AFR = auto fault recovery,
0 = manual
1 = auto
XRF = External reference status, N/A = no external reference,
05M for 5 MHz, and 10M for a 10 MHz
LRS = 1-Serial, 2-Ethernet, 3-Serial and Ethernet
Example:
RCS = ’cr’
AMP = 1’cr’
MUT = 1’cr’
ONL = 1’cr’
ESW = 1’cr’
AOF = 00.00’cr’
AFR = 1’cr’
XRF = N/A’cr’
RCS=
RCS?
RCS=x….x
(See
description for
details of
arguments)
Summary of Contents for LGAN
Page 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Page 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Page 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Page 117: ......
Page 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...