LGaN
Revision 0
Serial Interface Operation
5–16
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
High Power
Threshold
HPT=
5 bytes
Command or Query.
This command allows the user to set the threshold for the high
forward power alarm/fault. If the forward power rises above the
specified value, the alarm/fault will be indicated. Setting this
parameter to 00.00 effectively disables the threshold.
HPT=xx.xx,
Where:
xx.xx = a real number between 48.00 37.00 and 64.00 57.00 dBm.
(Glenn note: This was wrong for the 1kW, it was 40-60 dBm.)
Example:
<1/HPT=56.00’cr’
>0001/HPT=’cr’’lf’
Default Value: 00.00
HPT=
HPT?
HPT*
HPT?
High Power
Threshold
Initialize Events
Pointer
IEP=
None
Command only.
Resets internal pointer to allow RNE? Queries to start at the
beginning of the stored events log.
Example:
<1/IEP=’cr’
>0001/IEP=’cr’’lf’
IEP=
IEP?
IEP*
N/A
N/A
Software Image IMG=
1 byte
Command or Query.
Current Active software image,
Where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
Examples:
<1/IMG=1’cr’ (instructs the unit to load firmware from image #1 at
the next reset / power up).
<1/IMG?’cr’ (queries the image number that the firmware loaded
during bootup)
Note: If the user sends the IMG command, and then queries the IMG
value, the numbers may not be equal because the command
tells the firmware which image to boot from at the next bootup,
and the query reports the image that the firmware booted from
on the last bootup.
IMG=
IMG?
IMG*
IMG#
IMG?
IMG=x
(See
description for
details of
arguments)
Summary of Contents for LGAN
Page 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Page 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Page 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Page 117: ......
Page 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...