LGaN
Revision 0
Serial Interface Operation
5–22
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Mute State
MUT=
1 byte
Command or Query.
Mute the unit
Where:
0 = Disable (Not Muted)
1 = Enable (Muted)
2 = Aux Mute (Muted) [Query Only, AUX]
Example:
<1/MUT=1’cr’
>0001/MUT=1’cr’’lf’
Default Value: 0
MUT=
MUT?
MUT*
MUT?
MUT=x
(Same format
as command
arguments)
Number of
Unread Stored
Events
N/A
3 bytes
Query only.
Unit returns the Number of stored Events, which remain Unread in
the form of xxx.
Example:
<1/NUE?’cr’
>0001/NUE=126’cr’’lf’
NUE=
NUE?
NUE=xxx
Number of
Unread Stored
Statistics
N/A
3 bytes
Query only.
Unit returns the Number of stored Statistics, which remain Unread in
the form of xxx.
Example:
NUS=126
NUS=
NUS?
NUS=xxx
Equipment
Odometer
N/A
6 bytes
Query.
Used to view or clear the equipment odometer (stored in non-volatile
memory) in the format of aaaaaaaaaa
Where:
aaaaaaaaaa = The time in hours of the odometer.
Example: EOD?
EOD=
EOD*
EOD?
EOD=aaaaaa
(see
description for
details of
return string)
Part Number
N/A
96 bytes
alphanumeric
Query only.
The PNM query will return the DOTCODE string that was loaded
into the unit.
Example:
<1/PNM?
>0001/PNM=TRP0.0000000200’cr’’lf’
PNM=
PNM?
PNM *
PNM?
PNM=x….x
(See
description for
details of
return string)
Summary of Contents for LGAN
Page 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Page 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Page 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Page 117: ......
Page 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...