LGaN
Revision 0
Serial Interface Operation
5–13
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Circuit
Identification
CID=
80 bytes
Command or Query.
CID is a user-defined string of data that may be used to identify or
name the unit or station. The CID is an 80-byte field of data that is
entered as one line, but it will be read back from the unit as two 40-
byte lines of data.
Examples:
<1/CID= Station #001--SSPA #01--’cr’
>0001/CID=
<1/CID?’cr’
>0001/CID=’cr’
Station #001--SSPA #01--’cr’’lf’
Default Value:
--------------CUSTOMER ID---------------
----------------MESSAGE-----------------
CID=
CID?
CID*
CID?
CID=x…x
(See
description for
details of
arguments)
Calibrate LNB
Current
CLC=
N/A
Command or Query.
The CLC command stores the value of the LNB Current Supply (in
mA) as a reference point. The LNB current alarm point is then
determined by the calibrated LNB reference point, and the LNB
current window setting (see LCW command).
Note: this command will return a mode error if the LNB current source
output has not been enabled first (see LCS command).
Example: <1/CLC=’cr’
>0001/CLC=’cr’’lf’
The CLC query will return the value that was stored during the
LNB current calibration.
Example: <1/CLC?’cr’
>0001/CLC=xxx.x
Where:
xxx.x is the calibrated LNB current value in mA.
Default Value: 000.0
CLC=
CLC?
CLC*
CLC?
CLC=xxx.x
(See
description
for details of
arguments)
Clear Statistics
Log
CSL=
1 byte
Command only.
Used to clear the statistics log entries.
Example:
<1/CSL=1’cr’
>0001/CSL=’cr’’lf’
CSL=
CSL?
CSL*
N/A
CSL=
Summary of Contents for LGAN
Page 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Page 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Page 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Page 117: ......
Page 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...