CDM-710G High-Speed Satellite Modem
Revision 1
Remote Control
MN-CDM710G
A–2
A.3
RS-232
This a much simpler configuration in which the controller device is connected directly to the
target via a two-wire-plus-ground connection. Controller-to-target data is carried, via RS-232
electrical levels, on one conductor, and target-to-controller data is carried in the other direction on
the other conductor.
A.4
Basic Protocol
Whether in RS-232 or RS-485 mode, all data is transmitted as asynchronous serial characters,
suitable for transmission and reception by a UART. In this case, the asynchronous character
formats is 8N1. The baud rate may vary between 1200 and 57,600 baud.
All data is transmitted in framed packets. The controller is assumed to be a PC or ASCII dumb
terminal, which is in charge of the process of monitor and control. The controller is the only
device which is permitted to initiate, at will, the transmission of data. Targets are only permitted
to transmit when they have been specifically instructed to do so by the controller.
All bytes within a packet are printable ASCII characters, less than ASCII code 127. In this
context, the Carriage Return and Line Feed characters are considered printable.
All messages from controller to target require a response (with one exception). This will be either to
return data which has been requested by the controller, or to acknowledge reception of an instruction
to change the configuration of the target. The exception to this is when the controller broadcasts a
message (such as Set time/date) using Address 0, when the target is set to RS-485 mode.
A.5
Packet Structure
Controller-to-Target
Start of Packet
Target
Address
Address
De-limiter
Instruction
Code
Code Qualifier
Optional
Arguments
End of Packet
<
ASCII code 60
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
=
or
?
ASCII code 61
or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Example:
<0135/TFQ=0070.2345{CR}
Target-to-Controller
Start of Packet
Target
Address
Address
De-limiter
Instruction
Code
Code Qualifier
Optional
Arguments
End of Packet
>
ASCII code 62
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
=
,
?
,
!
, or
*
ASCII code 61,
63, 33 or 42
(1 character)
(From 0 to n
characters)
Carriage Return,
Line Feed
ASCII code
13,10
(2 characters)
Example:
>0654/TFQ=0070.2345{CR}{LF}
Summary of Contents for CDM-710G
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 26: ...CDM 710G High Speed Satellite Modem Revision 1 Preface MN CDM710G xx Notes...
Page 48: ...CDM 710G High Speed Satellite Modem Revision 1 Introduction MN CDM710G 1 22 Notes...
Page 130: ...CDM 710G High Speed Satellite Modem Revision 1 Front Panel Operation MN CDM710G 6 54 Notes...
Page 150: ...CDM 710G High Speed Satellite Modem Revision 1 SNMP Interface MN CDM710G 8 4 Notes...
Page 160: ...CDM 710G High Speed Satellite Modem Revision 1 Clock Modes MN CDM710G 10 6 Notes...
Page 180: ...CDM 710G High Speed Satellite Modem Revision 1 HSSI Interface CDI 60 MN CDM710G 13 6 Notes...
Page 246: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...