3.3.2.2 AC Operation – Replacing Fuses
The CDD-56xA/L uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral connections.
The fuses are contained within a fuse holder that is press-fit into the body of the IEC power module
(located on the rear panel, Figure 3-4).
Figure 3-4. Replacing CDD-56xA/L AC Fuses
WARNING
Disconnect the power supply first.
To replace the fuse(s):
1.
Disconnect the power supply.
2.
Unseat the fuse holder from the IEC power module.
a.
Use the slot to pry the holder outward from the IEC power module.
b.
Pull the holder straight out, and then swing the holder away from the module.
3.
Remove and replace the T2 (2.00 Amp) fuses as needed.
4.
Re-seat the fuse holder in the IEC power module.
CAUTION
For continued operator safety, always replace the fuses with the correct type and rating.
See Table 3-2.
Table 3-2 Correct Fuses
Model
Input
Power Consumption
Fuse
CDD-564A
AC
100-240VAC, 50-60HZ, 0.62-0.26A 1A
CDD-564AL
AC
100-240VAC, 50-60HZ, 1.24-0.52A 2A
CDD-562AL
AC
100-240VAC, 50-60HZ, 0.75-0.31A 1A
CDD-564A
DC
43-60VDC, 1.43-1.1A
2A
CDD-564AL
DC
43-60VDC, 2.9-2.1A
4A
CDD-562AL
DC
43-60VDC, 1.73-1.25A
2.5A