CDD-562AL/564A/L Multi-Channel Demodulator
Revision 0
Ethernet-based Remote Product Management
MN-CDD562AL564AL
7–6
CAUTION
Changing the Working mode between Point-to-Point Mode, Small Network Mode,
Large Network Mode, and Vipersat Mode causes the system to reboot. The system
configuration is saved before re-booting. Make sure you set the correct value.
7.3.8.1.4
3xDES Decryption Subgroup (EN version only)
This subgroup controls the parameters for the 3xDES feature. Each Receive key length is 192 bits. Enter
the Rx DES keys using the DESRxKeyTable.
7.3.8.1.5
SNMP Traps Subgroup
This subgroup controls where SNMP traps are sent and the community string used in sending traps. Either
SNMPv1 or SNMPv2 traps can be sent.
7.3.8.2 Configuration Group
7.3.8.2.1
Interface Group
This group controls the parameters of the unit’s Ethernet and demodulator interfaces.
7.3.8.2.1.1 Ethernet Interface Subgroup
This subgroup defines the unit’s Ethernet interface. These include parameters for setting the Ethernet
speed, IP address and IP address subnet prefix length.
7.3.8.2.1.2 Demodulator Interface Subgroup
This subgroup defines the Demodulator’s interfaces and each demodulator’s HDLC addresses.
CAUTION
HDLC Address Mode has been changed to be read-only. This parameter is now
settable through the Working Mode OID (cdd564aWorkingMode) in the Features
subgroup.
7.3.8.2.2
Route Table Group
Use this group to control how the packets that the unit receives are routed.