Configuring the Printer
A78408098-005
48
Adjusting the Tear-Off Position
HEX DUMP NO
↑
TEAR ADJUST: - 30
→
or
←
TEAR ADJUST: ...
→
or
←
TEAR ADJUST: +360
→
or
←
↓
STORE? QUIT
TEAR ADJUST: xxxx
These values adjust the distance between the
Tear-Off Perforation and the Tear-Off Bar. The
values correspond to 1/180 inch units, i.e. the
tuning ranges between -1/6 and 2 inch. Default: 0.
See also “How to Use the Tear-Off Function”, later in this Chapter.
Storing the values
TEAR ADJUST: xxxx
↑
STORE? QUIT
→
or
←
STORE? SAVE
→
or
←
STORE? CURRENT
→
or
←
PROG
EXIT
STORE? QUIT
This setting does not save any of the new values set.
The values set previously will be used.
STORE? SAVE
The values set are stored permanently (in the NVM)
and will be used until they are changed by the
operator.
STORE? CURRENT
The values set are valid until the printer is turned off.
When you turn the printer on again, the values set in
the preceding menu setup will be used.
At this point the Program Configuration Setup is finished. You exit pressing the
PROGRAM key.