ELECTRICAL
Output
25 Amps ac 3% into any load - short circuit to 100
milliohms.
Maximum Voltage Output:
6V
Pass/Fail Criterion
100 milliohms. 100 milliohm calibration resistor
supplied. (Contact factory for custom settings)
Ramp Time
10 msec
Test Duration Timer
0-25 sec. approx.
Duty cycle
100 %
ENVIRONMENTAL
Operating Temperature
15-35 C
Relative Humidity Range
0-90% non-condensing
GENERAL
Input power requirements
See rear panel for input voltage and fuse ratings
Weight
11 lbs
Table 1-1. GF-30AC-T Specifications
Non-Detachable Cordset AWG
Non-Detachable Cordset Maximum Length
18
6 feet
16
10 feet
14
14 feet
12
20 feet
Table 1-2. GF-30AC-T Non-Detachable Cordset Maximum Length.