7-24
Cabling
For use with Intel Pentium II Xeon processor-based servers only
Writer: Salvo Project: Compaq ProLiant 5500 Servers Setup and Installation Guide Comments: 328470-001
File Name: H-CH07.DOC Last Saved On: 7/13/98 11:24 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Example 1:
Using Integrated SCSI Port 1 and Port 2 for
Hard Drives with SCSI Input 1 Connected to
the Removable Media Bay
1. Install the Duplex Enabler Board on the back of the Drive Cage, if not
already installed.
2. Connect 19-inch point-to-point non-terminated SCSI cable (199606-
007), from the SCSI Port 1 to SCSI Input 0 of the duplex board. Connect
another 19-inch point-to-point non-terminated SCSI cable (199606-007)
from SCSI Port 2 to SCSI Input 1 of the duplex board. These
connections are shown in Figures 7-13 and 7-14.
3. Use 22-inch 3-device non-terminated SCSI cable (199616-010),
supplied with server, to connect from the duplex enabler board to the
removable media bay.
0
0
1
1
2
2
3
3
0
0
1
1
2
2
3
3
2
5
8
4
7
10
1
3
6
9
Figure 7-13. Example 1: Configuration diagram