Specifications
6-2
Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 10/24/01 1:59 PM
System Unit
Table 6-1: System Unit Specifications
Dimensions
Height (without feet)
4.19 cm
1.65 in
Depth
65.45 cm
25.75 in
Width
42.55 cm
16.75 in
Weight (maximum)
11.81 kg
26 lb
Weight (no drives installed)
9.54 kg
21 lb
Input
requirements
Rated input voltage
100 VAC to 240 VAC
—
Rated input frequency
50 Hz to 60 Hz
—
Rated input current
2.8 A (110 V) to 1.4 A (220 V)
—
Rated input power
307 W
—
BTUs per hour
1048
—
Power supply output
Rated steady-state power
180 W
—
Maximum peak power
200 W
—
Temperature
range
Operating (See note)
10
°
C to 35
°
C
50
°
F to 95
°
F
Shipping (See note)
-40
°
C to 70
°
C
-40
°
F to 158
°
F
Relative humidity
(noncondensing)
Operating (See note)
10% to 90%
—
Non-operating (See note)
5% to 95%
—
Maximum wet bulb
temperature
28
°
C
82.4
°
F
Note:
Operating temperature has an altitude derating of 1°C per 1,000 ft. No direct sunlight.
Storage maximum humidity of 95% is based on a maximum temperature of 45°C. Altitude minimum