Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
2-1
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 3:47 PM
2
Removal and Replacement Procedures
This chapter provides subassembly/module-level removal and replacement procedures for
Compaq ProLiant DL360 Generation 2 servers. No tools are required to service the server.
After completing all necessary removal and replacement procedures, it is recommended that
server diagnostic programs be run to verify that all components are operating correctly.
The following Diagnostic programs, from the
SmartStart
TM
and Support Software CD, may be
used:
•
Compaq System Configuration Utility
•
Compaq Array Diagnostic Utility (ADU)
In addition the Compaq Server Diagnostics program may be run. This program is available
from the Compaq website at
www.compaq.com/support/files/server/us
Electrostatic Discharge Information
A discharge of static electricity can damage static-sensitive devices or micro circuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To
prevent electrostatic damage, observe the following precautions:
•
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
stations.
•
Cover workstations with approved static-dissipating material. Use a wrist strap connected
to the work surface and properly grounded tools and equipment.
•
Keep the work area free of nonconductive materials such as ordinary plastic assembly
aids and foam packing.
•
Always be properly grounded when touching a static-sensitive component or assembly.
•
Avoid touching pins, leads, or circuitry.
•
Always place drives PCB assembly-side down.
•
Use conductive field service tools.