Removal and Replacement Procedures
2-24
Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 3:47 PM
AC Power Cord and Line Filter
To remove the AC power cord and line filter:
1. Power down the server. See “Powering Down the Server” in this chapter.
2. Remove the server from the rack. See “Removing the Server from the Rack” in this
chapter.
3. Remove the access panel. See “Server Access Panel” earlier in this chapter.
4. Remove the PCI riser board assembly. See “PCI Riser Board Assembly” in this chapter.
5. Using a finger, lift the line filter off the chassis retaining stud and release the line filter
from the chassis mount
.
6. Slide the power cord retaining clip
upward to free the AC power cord.
2
1
Figure 2-20: Releasing the AC power cord and line filter
7. Lift the AC power cord and filter free of the server chassis.